Self Diagnosis
Indications
Inlet hot water sensor disconnected or not
inserted
1
2
3
4
No.
LEDs of water temp. Med & Low
blinking simultaneously
Inlet hot water sensor short-circuited and
temperature excessively increased.
LEDs of water Med & High level
blinking simultaneously
Outlet hot water sensor disconnected or not
inserted
LED hot water temp. Med & Low
blinking separately
Outlet hot water sensor short-circuited and
temperature excessively increased
LED hot water temp. Med & High
blinking separately
Please refer to the following table for the exact status when requesting
repair service.
Please refer to the following table for the exact status when requesting
repair service.
Item
Wash
Heated
Seat
Dimension
Weight
Net Weight
(Gross Weight)
Dry
Feed
Volume
BM-2000P
Rated Voltage
AC 120V, 60Hz
Max. Power Consumption
1270W
Power Cord Length
4ft.
Water Feed Method
Directly connected to water pipe
Recommended Water Inlet Pressure
99~106.6 psi
0.16 gal/min
Wash
0.16 gal/min
Bidet
0.13 gal/min
Power Wash
5 Levels
Pressure Control
Room temp.~100°F
Temperature Control
1200 W
Heater Capacity
Temp. Fuse, Thermo Switch
Safety Device
Room temp.~107°F
Temperature Control
55W
Heater Capacity
Temp.Fuse
Safety Device
Room temp. ~122°F
Temperature Control
18.5” x 20.8” x 5.7”
BM-2000P-E
10.6lb (17.3)
BM-2000P-E
10.5lb (17.2)
BM-2000P-R
18.5” x 19.5” x 5.7”
BM-2000P-R
250W
Heater Capacity
Temp Fuse, Bi-metal
Safety Device
Catalytic Deodorization
Deodorization
Repair & Specifications
9
Error/Issue
What to Check
Before Requesting Repair
Self-Diagnosis Table
Specifications
Completely out of operation
• Check if the power plug is not connected
• Check for power failure
Water pressure is low
• Check if water pipe filter is blocked by foreign material
• Check if the water pressure is set at too low a level
5
Seat sensor disconnected or not inserted
LED seat temperature Low blinking
9
Deodorizing motor: Check the cycle of
rotation at low speed
Buzzer sounds. Abnormal condition
is differently indicated by symptoms
10
Stoppage of motor due to the over-current
of deodorization motor
11
Heat stops in case of low speed rotation of
drying motor
12
Heater and drying motor simultaneously stop
in case of the over-current of drying motor
6
Seat sensor short-circuited and temperature
excessively increased
LED seat temperature High blinking
7
Air pump motor disconnected or not
inserted
Wash, Bidet, Power Wash, are out of
operation
8
Air pump motor short-circuited
Water is not warm enough
• Check if its temperature is set at ‘Off’ or ‘Low’
Seat is not warm enough
• Check if its temperature is set at ‘Off’ or ‘Low’
Water does not spray out
• Check if the water supply is suspended
• Check if the water feed valve is locked
• Check if the nozzle is blocked by foreign material
• Check if connection hose is bent