Technical information
14
4.6
Technical data mod.
M96.32SR/...
Heat input
(A)
Nominal
kW
BTU/h
33,3
113 624
Minimum
kW
BTU/h
15,7
53 570
Useful output G20
Maximum
kW
BTU/h
32,2
109 870
Minimum
kW
BTU/h
15,0
51 182
Maximum condensing
kW
BTU/h
34,4
117 377
Minimum condensing
kW
BTU/h
15,6
53 229
Useful output G30 G31
Maximum
kW
BTU/h
32,2
109 870
Minimum
kW
BTU/h
15,0
51 182
Maximum condensing
kW
BTU/h
34,4
117 377
Minimum condensing
kW
BTU/h
15,6
53 229
Central heating
Maximum flow temp.
û
C
85
Minimum flow temp.
û
C
38
Minimum return temp.
û
C
30
Maximum pressure
kPa
bar
250
2,5
Minimum pressure
kPa
bar
30
0,3
Available head
(in 1000 l/h)
kPa
bar
25
0,25
Seasonal efficiency
G20
(B)
band
%
B
86,8
Seasonal efficiency
G30 G31
(B)
band
%
B
88,8
Gas supply pressures
Gas
Natural
G20
Butane
G30
Propane
G31
Norm.
Pa
mbar
2 000
20
2 900
29
3 700
37
Max
Pa
mbar
2 500
25
3 500
35
4 500
45
Min.
Pa
mbar
1 700
17
2 000
20
2 500
25
1 mbar approximately equals 10 mm H
2
O
Gas pressures at the burner
Gas
Natural
G20
Butane
G30
Propane
G31
Max.
Pa
mbar
1300
13,0
2720
27,2
3600
36,0
Min.
Pa
mbar
270
2,7
550
5,5
730
7,3
Ignition Pa
mbar
600
6,0
1200
12,0
1300
13,0
1 mbar approximately equals 10 mm H
2
O
(A)
referred to the net calorific value at 15
û
C and 1013,25 mbar
G 20 = 34,02 MJ/m
3,
G 30 = 45,6 MJ/kg, G 31 = 46,4 MJ/kg
(B)
The value is used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating
of dwellings. The test data from which it has been calculated have been certified by a notified body.