Technical information
13
Gas rate
Gas
Natural
G20
m
3
/h
Butane
G30
kg/h
Propane
G31
kg/h
Max.
3,07
2,29
2,25
Min.
1,28
1,03
1,01
Injectors
Natural G20
130
Butane G30
75
Propane G31
75
Electrical Data
Voltage
V~
230
Frequency
Hz
50
Power consumption
W
150
Protection degree
IPX4D
External fuse rating
A
3
Internal fuse rating
A
F1---F2 3,15 AF
Flue design
Flue pipe diameter
Coaxial
mm
60/100
Twin split pipes
mm
80
Roof
mm
80/125
Nominal heat flow rate
(A)(C)
kW
29,0
Exhaust temperature
(C)
û
C
90
Mass flow rate
(C)
g/s
21,1
Flue gas figures
Nominal heat input
(A)(C)
kW
29,0
CO
2
content
%
6,8
O
2
content
%
10,7
CO content
ppm
75
Exhaust temperature
(C)
û
C
90
Other specifications
Height
mm
803
Width
mm
400
Depth
mm
350
Weight (dry)
kg
44,5
Water volume in the boiler
(up to 1 bar)
l (kg)
2,2
(C)
Values refer to tests with a 1 m chimney working at the nominal heat input
IN
ST
A
LL
ATION