Technical information 

20 

 

Capacity 

Объем

 

l 6,0 

 

Pre-load pressure 

Предварительное

 

давление

 

kPa 
bar 

100 
1,0 

 

Maximum volume of 
water in the system 

Максимальный

 

объем

 

воды

 

в

 

системе

 

l 132 

 

Tab. 4.1 

 

 

 

 

* Where conditions are: 

 

*

При

 

условиях

-

 

Average maximum temperature of the 
system is 80°C 

 

-

 

Средняя

 

максимальная

 

температура

 

в

 

системе

 80 

градусов

 

С

 

-

 

Initial temperature when filling up the 
system is 10°C 

 

-

 

Начальная

 

температура

 

воды

 

при

 

заполнении

 

системы

 10 

градусов

 

С

 

For systems with volumes greater than 132l, 
an additional expansion vessel must be 
provided. 

 

Для

 

систем

 

с

 

объемом

 

более

 132 

литров

необходима

 

установка

 

дополнительного

 

расширительного

 

бака

 

21 

 

5. Installation 

 

5. 

Монтаж

 

5.1. Warnings 

 

5.1 

Предупреждения

 

The use of gas appliances is subject to 
statutory control; it is essential to observe 
the current regulations and laws in force. 

 

Использование

 

газовых

 

приборов

 

подлежит

 

контролю

следует

 

выполнять

 

установку

 

в

 

соответствии

 

с

 

действующими

 

нормами

 

и

 

законодательством

The appliance must discharge combustion 
products directly outside or into a suitable 
exhaust duct designed for this purpose. 

 

Продукты

 

сгорания

 

должны

 

выводиться

 

прямо

 

на

 

улицу

 

или

 

в

 

предназначенный

 

для

 

этих

 

целей

 

дымоход

.  

The boiler must be installed close to the 
chimney flue pipe. 

 

Котел

 

должен

 

быть

 

установлен

 

рядом

 

с

 

дымовой

 

трубой

This boiler may be installed only in an 
adequately ventilated room in conformity with 
the standards. 

 

Котел

 

должен

 

быть

 

установлен

 

только

 

в

 

хорошо

 

вентилируемом

 

помещении

 

в

 

соответствии

 

с

 

действующими

 

стандарами

A minimum air flow rate of 2 m3/h per kW of 
max heat input must be ensured. 

 

Необходимо

 

обеспечить

 

расход

 2m3/

час

 

на

 

Квт

 

или

 

должен

 

быть

 

обеспечена

 

макс

потребляемая

 

мощность

For LPG, the appliance must also conform 
with the requirements of the distributors and 
comply with current Regulations and laws in 
force. 

 

При

 

использовании

 

сжиженного

 

газа

 

необходимо

 

также

 

производить

 

установку

 

котла

 

в

 

соответствии

 

с

 

рекомендациями

 

продавца

существующими

 

положениями

 

и

 

действующим

 

законодательством

The safety relief valve must be connected to 
a suitable drain, or discharge in a safe 
manner. 

 

Предохранительный

 

клапан

 

должен

 

быть

 

соединен

 

с

 

системой

 

канализации

 

или

 

иным

 

образом

 

обеспечивать

 

безопасный

 

слив

 

системы

The electrical wiring must conform with 
current Regulations, in particular: 

 

Электрические

 

соединения

 

должны

 

соответствовать

 

следующим

 

нормам

а

 

именно

-

 

the boiler must be earthed using the 
correct bonding clamp. 

 

-

 

котел

 

должен

 

быть

 

заземлен

 

соответствующим

 

образом

-

 

a fused spur isolation switch, with a gap 
of at least 3 mm between the contacts 
must be installed near to the boiler. 
Refer to section 5.8 in this chapter for 
the electrical connections. 

 

-

 

Атоматический

 

выключатель

 

с

 

минимальным

 

зазором

 

между

 

контактами

 3 

мм

 

должен

 

быть

 

установлен

 

в

 

непосредственной

 

близости

 

от

 

котла

Для

 

электрических

 

подключений

 

обратитесь

 

к

 

разделу

 5.8 

данной

 

главы

.  

In no circumstances will the manufacturer 
be held responsible if the warnings and 
instructions contained in this manual have 
not been complied with. 

 

Производитель

 

не

 

несет

 

ответственности

если

 

не

 

были

 

соблюдены

 

все

 

инструкции

содержащиеся

 

в

 

настоящем

 

руководстве

5.2.  Precautions for installation 

 

5.2 

Меры

 

предосторожности

 

при

 

монтаже

 

For the installation proceed as follows: 

 

Чтобы

 

приступить

 

к

 

монтажу

выполните

 

следующее

Содержание PARVA CONTROL M90.24AV

Страница 1: ...1796211072 17962 1107 2 4606 52A5 PARVA CONTROL MODEL M90 24AV USER MANUAL AND INSTALLATION INSTRUCTIONS...

Страница 2: ...erous to obstruct even partially the air intakes used to aerate the room where the boiler is installed to use extractor fans fire places and the like in the same room at the same time as the boiler to...

Страница 3: ...the gas cocks get the assistance of a qualified person Do not touch the appliance with parts of the body that are wet or damp and or bare feet In case of structural work or maintenance near the exhaus...

Страница 4: ...ng the addition of an external control you can eliminate the boiler from your fault analysis Do not forget to range rate the boiler to suit the system requirements This procedure is covered in the com...

Страница 5: ...e boiler to follow the timed settings Some products incorporate an anti cycling time delay It is normal when first switching the boiler on for the boiler to operate on heating for a few seconds then s...

Страница 6: ...1 Warnings 39 7 2 Procedures 39 8 Maintenance 8 1 Warnings 41 8 2 Dismanting the external panels 41 8 3 Emptying the ch system 42 8 4 Cleaning the primary heat exchanger 42 8 5 Checking the pressurisa...

Страница 7: ...e left hand side panel adjacent to the data badge the self adhesive label included with the conversion kit indicating the type of gas and the gas pressures to which the appliance has been set 11 12 Re...

Страница 8: ...tructions relating to the procedures for adapting the boiler to the type of gas available and subsequent calibration described below are presented in sections 6 5 and 6 6 6 5 6 6 7 2 Procedures 7 2 1...

Страница 9: ...ur Fill in the details required on the Boiler Guarantee Certificate and hand to the User advising them to return the correct section for boiler Guarantee registration Finally advise the User that for...

Страница 10: ...s normally provided by the installer for this purpose 2 2 If you are in any doubt regarding this procedure you are advised to contact your Installer or an Approved Engineer This appliance is provided...

Страница 11: ...ment potentiometer marked RISC Fig 6 8 Rotating the potentiometer anti clockwise reduces the maximum supply current to the gas modulator device and thus reduces the gas pressure to the burner RISC 6 8...

Страница 12: ...e operation light 9 will flash every 2 seconds operating boiler 4 7 2 5 9 2 Commissioning 35 6 6 Adjusting the burner ignition 6 6 1 Turn off the boiler by means of the fused spur isolation switch pro...

Страница 13: ...ment will be necessary A full explanation of the gas pressure adjustment procedure is given in the Gas Valve section of the service manual If maximum and or minimum gas pressures are adjusted then the...

Страница 14: ...iance operation light 9 will flash every 4 seconds 7 2 9 9 4 Commissioning 33 5 Set the d h w and c h temperature control knobs to their maximum position 5 6 Switch on the boiler and if external contr...

Страница 15: ...panel of the case see section 8 2 in this manual 1 8 2 2 Open the gas valve inlet pressure test point 36 in Fig 6 5 at the valve input connect a suitable pressure gauge check the gas pressure of the s...

Страница 16: ...ll turn and leave open permanently 3 21 6 2 1 4 Open the C h circuit filling valve 12 in Fig 6 1 and fill the C h circuit see section 2 2 4 12 6 1 2 2 5 Open each radiator air release tap starting wit...

Страница 17: ...be inspected and cleaned This service can be part of a maintenance contract In particular you are advised to have the following checks carried out primary heat exchanger domestic hot water storage tan...

Страница 18: ...ter comes out of the pressure relief valve Check that the C h circuit filling valve is closed as described in the section 2 2 of this manual 2 2 Check on the temperature and pressure gauge 4 on sectio...

Страница 19: ...ting it upwards 5 14 Connect the two temperature probe wires between D h w storage tank temp probe terminals Fig 5 15 5 15 Insert D h w storage tank temp probe in the longest probe sheath Fig 5 16 5 1...

Страница 20: ...on switch Fig 5 11 T 1 2 L N 3 Room thermostat Power supply terminal block External controls terminal block Fig 5 12 5 Connect the electrical supply flexible cord coming from the fused spur isolation...

Страница 21: ...to facilitate the operations on the internal parts 3 5 9 45 4 Loosen the screws J and remove the service panel Fig 5 10 4 J 5 10 For the electrical connection to the boiler use electric wires which co...

Страница 22: ...C h temp probe NTC Primary circuit flow switch Three way diverter valve D h w storage tank temp probe NTC NTC Pump Gas valve Installation 25 5 7 Installing the D h w storage tank 5 7 D h w storage tan...

Страница 23: ...l information 17 4 4 Technical Data mod M90 24AV 4 4 Nominal heat input kW 26 6 Minimum heat input kW 11 0 Maximum useful output kW 24 0 Minimum useful output kW 9 3 Central heating Temp regulation ra...

Страница 24: ...ney working at the nominal heat input 1 Installation 23 5 3 Installing the bracket 5 3 Precautions Utilise the paper template supplied with the boiler to determine the fixing position for the bracket...

Страница 25: ...by promoting formation of a protective skin on metal surfaces and neutralising gases present in the water Technical information 19 4 5 Hydraulic specifications 4 5 0 00 0 10 0 20 0 30 0 40 0 50 0 2 0...

Страница 26: ...d only in an adequately ventilated room in conformity with the standards A minimum air flow rate of 2 m3 h per kW of max heat input must be ensured 2m3 For LPG the appliance must also conform with the...

Отзывы: