- 68 -
INST
ALLA
TION
ADVANCED COMMISSIONING
Fig. 8.30
bar
RESET
•
By using buttons 15 or 16 (Fig. 8.29) it is
possible to modify the value of parameter
A49:
39
= factory reset
•
Press 12 or 13 (Fig. 8.29) to confirm the
value entered and return to the list of pa
-
rameters (Fig. 8.30).
•
Press the 17 (Fig. 8.29) to exit “program
-
ming mode”.
8.9 Settings for changing the
control board
When the control board is replaced, it must
be configured for the exact boiler type.
•
Enter “programming mode” by holding
down buttons 17 and 18 for 5 seconds at
the same time (Fig. 8.31). The code
P00
appears on the display, indicating entry
into “parameter P00” (Fig. 8.32).
Fig. 8.31
12
13
14
15
16
17
18
Fig. 8.32
bar
RESET
•
Scroll through the various parameters us
-
ing 12 or 13 until the LCD display shows
the message
Cod
, indicating entry into
“parameter Cod” (Fig. 8.33), and then dis
-
plays three dashes “
- - -
”.
Fig. 8.33
bar
RESET
•
Press the 16 button to set “
2 - -
”, then
press 12 to confirm the 2 and go to the
next segment.
•
Press the 16 button to set “
2 7 -
”, then
press 12 to confirm the 7 and go to the
next segment.
•
Press the 16 button to set “
2 7 5
”, then
press 12 to confirm the 5 and go back to
the list of parameters.
• The code
P10
appears on the display, in
-
dicating entry into “parameter P10” (Fig.
8.34).
Fig. 8.34
bar
RESET
•
By using buttons 15 or 16 (Fig. 8.31) it is