- 63 -
INST
ALLA
TION
COMMISSIONING
Fig. 7.27
0
2
1
8
1
21
1 5
6
3
9
Press buttons
•
and
at the same
time to enter transparent programming
( Fig. 7.28 ).
Fig. 7.28
Press buttons
•
or
to display
the
"PM11"
program of the pump post-
circulation ( Fig. 7.29 ).
Fig. 7.29
To modify the programmed SET, act on
•
buttons
or
and wait for the
programmed number to fl ash ( Fig. 7.30 ).
Each step increased or decreased corre-
sponds to 1 second.
Fig. 7.30
To exit programming, press button
•
.
Selecting the reignition fre-
7.13
quency
When the boiler functions in normal on/off
heating mode, the minimum time between
two ignitions is set at three minutes (re-igni-
tion frequency).
This time can be changed by a minimum of
zero to a maximum of eight and a half min-
utes by acting on programming both from
the panel controls and the remote control.
Enter the "programming mode" by press-
•
ing keys 15 - 16 - 17 ( Fig. 7.31 ) for 10 sec-
onds at the same time until the letters
Pr
that alternate with code
01
are displayed
on the LCD display, indicating that "param-
eter 01"( Fig. 7.32 ) has been activated.
Fig. 7.31
13
14
15
16
17