background image

 

FRONT & REAR PANEL FEATURES 

 

on

signal

peak

temp

fault

MXA300

3

2

1

4

5

6

master

bass

0

+

0

+

treble

 

 

On Indicator:

  This green LED remains lit when AC power is 

applied to the unit.

 

 
Signal/Clip Indicator:

  This 2-color LED indicates the signal 

level for the amplifier.  When the LED is green, the amplifier has 
signal (above -30dB).  When the LED is red, the amplifier signal 
is clipping (max. power).  

CAUTION:

  Signal levels should be 

adjusted to avoid clipping.  Clipping can cause distortion, over- 
temperature conditions, and even loudspeaker damage.

 

 

Temp/Fault Indicator 

(not present on model MXA35)

:

  This red 

LED indicates over-temperature and output fault conditions for 
the amplifier.  When the LED remains lit, the amplifier has an 
over-temperature condition.  When the LED is flashing, the 
amplifier has an output fault condition.  Either condition will 
temporarily de-activate the amplifier, causing the Signal/Peak 
LED to turn off as well.  The amplifier will attempt to self-reset 
once the over-temperature or output fault condition is resolved. 

NOTE:

  Signal/Peak indicators will turn off during Temp/Fault 

conditions (see Signal/Peak & Temp/Fault Indicators above).

 

 
Level (Channels 1~6): 

 These controls adjust the amount of 

signal sent from the individual input channels to the mixer 
output.  Optimum Level setting is near the 12 o'clock position 
(unity gain). 
 

Level (Master):

  This control adjusts the amount of signal sent 

from the mixer output to the amplifier input.  The Master Level 
control is used to adjust the overall volume of the system. 
 

Bass:

  This screwdriver control adjusts the low-frequencies 

("Bass") at the mixer output (±12dB @ 50Hz). 
 

Treble:

  This screwdriver control adjusts the high-frequencies 

("Treble") at the mixer output (±12dB @ 10kHz). 

 

input

1

input

2

channel 1

min

max

peak

channel 2

peak

trim

min

max

trim

min

max

trim

min

max

trim

min

max

trim

min

max

min

max

min

max

min

max

min

max

trim

input

3

channel 3

peak

input

4

channel 4

peak

input

5

channel 5

peak

input

6

channel 6

off

low cut

off

link

link

on
off
on

peak

auto mute
sensitivity

limiter

threshold

70V

100V

25V

class 2 wiring

class 3

wiring

com

pre out

+10V

C

EQ in

line out amp in

xfmr

input

4

Ω

gnd

chime

level

110-120/220-240V

~

  50-60Hz  300W

FUSE:  T  8A/4A  L  250V  120V/240V

Music
On
Hold
output

Music On
Hold level

remote
level
control

mute/chime

mic/line

tel

BIAMP SYSTEMS

120V

FU

SE

FU

SE

O

phantom pwr

priority

auto mute

manual mute

-80dB

`

 on

`

 on

`

 on

`

 on

-20dB

phantom pwr

priority

auto mute

manual mute

-80dB

`

 on

`

 on

`

 on

`

 on

-20dB

phantom pwr

priority

auto mute

manual mute

-80dB

`

 on

`

 on

`

 on

`

 on

-20dB

phantom pwr

priority

auto mute

manual mute

-80dB

`

 on

`

 on

`

 on

`

 on

-20dB

phantom pwr

priority

auto mute

manual mute

-80dB

`

 on

`

 on

`

 on

`

 on

-20dB

phantom pwr

priority

auto mute

manual mute

-80dB

`

 on

`

 on

`

 on

`

 on

-20dB

MXA300

UL

R

LISTED

52SJ

C

US

RoHS

Compliant

EU 2002/95/EC

WARNING:

  RISK OF HAZARDOUS ENERGY.

SEE INSTALLATION MANUAL.

Designed in Oregon, U.S.A.

Assembled in India

 

 

AC Power Entrance:

  The switch applies power to the unit.  The 

receptacle accepts the detachable Power Cord.  The Power Cord 
is for connection to three-prong grounded outlets.  

CAUTION:

  Do 

not remove or defeat the ground prong on the Power Cord, as this 
constitutes a shock hazard.  Equipment shall be connected to a 
mains socket outlet with a protective earthing connection.  Plug is 
main disconnecting device and it shall remain readily operable.

   

 

 

Fuse:

  Replace Fuse with same type and value only.  

NOTE:

  If 

the Fuse continues to blow, the amplifier may require service. 

 

Power Selector Switch:

  This switch selects either 120 Volt or 

240 Volt AC operation.

 

 

Output Connector:

  These screw terminals provide the speaker 

outputs from the amplifier.  

CAUTION:

  To reduce the risk of 

electric shock, do not perform any servicing unless you are 
qualified to do so.  Output connections must be made by qualified 
service personnel only (refer to Installation Instructions on pg. 4).

 

Chime Level:

  This control adjusts the volume level of a chime 

tone (see Mute/Chime below).  To turn the chime tone off 
completely, set this control to the counter-clockwise position (min). 
 

Limiter Threshold:

  This control adjusts the threshold level at 

which the internal limiter circuit is activated.  To turn the limiter off 
completely, set this control to the clockwise position (max). 
 

Auto Mute Sensitivity:

  This control adjusts the level at which 

signals from "priority" channels will automatically trigger muting of 
selected non-priority channels (see DIP Switches on next page).  
To increase auto mute sensitivity, turn this control clockwise. 
 

Mute/Chime:

  This terminal (plus the adjacent 

d

 terminal) allows 

manual muting of selected channels via an external switch or 
contact closure (see DIP Switches on next page).  When the 
Chime Level control is turned up (on), a pre-announcement chime 
tone will also be activated by the switch or contact closure. 

Содержание MXA Series

Страница 1: ...htning storms or when unused for long periods of time 13 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply co...

Страница 2: ...29Aug07...

Страница 3: ...ophone line input channels channel 1 selectable for 600 ohm transformer tel input rear panel trim peak indicator on each input channel 48 Volt phantom power selectable on each input channel automatic...

Страница 4: ...line tel BIAMP SYSTEMS 120V F U S E F U S E O phantom pwr priority auto mute manual mute 80dB on on on on 20dB phantom pwr priority auto mute manual mute 80dB on on on on 20dB phantom pwr priority au...

Страница 5: ...d as cut only This also precludes boosting of the Bass control see above in these applications DIP Switches The five DIP switches above each input are used to assign specific functions to those indivi...

Страница 6: ...utputs from the amplifier From the factory a jumper wire is installed from the 4 terminal direct output to the xfmr input terminal For transformer xfmr output connect speaker negative to the com termi...

Страница 7: ...al screws for the 100 volt tap and Com connections 4 Strip 0 25 6 4mm of insulation from each lead 5 Slide one piece of the supplied heat shrink tubing on to each wire 6 Crimp the ring lug terminals o...

Страница 8: ...range Tone Controls Treble Bass High Pass Filter Power Consumption MXA35 MXA75 MXA150 MXA300 Dimensions all models height 2 rack spaces width depth Weight MXA35 MXA75 MXA150 MXA300 Compliance 35 watt...

Страница 9: ...7 BLOCK DIAGRAM...

Страница 10: ...epairs or installed in any manner that does not comply with BIAMP Systems recommendations 4 Electro mechanical fans electrolytic capacitors and normal wear and tear of items such as paint knobs handle...

Страница 11: ......

Страница 12: ......

Страница 13: ......

Страница 14: ......

Отзывы: