background image

3

Unpacking 

The unit was carefully checked before leaving the factory. Inspect both the unit and its shipping

container for indication of improper handling. Report any equipment damage to the distributor immediately. If 
the unit was shipped to you, notify the shipping carrier without delay and place your claim. Unpack the unit. It is 
ready to be installed.

Description 

The Dynasound DS1092 incorporates a masking generator, music and paging mixer, and a power amplifier. 

The masking generator is an analog type for true Gaussian noise, and includes a pink / white switch and 

variable low-pass filter which is adjustable over a range of 800 to 8,000 Hz. The mixer includes a transformer-

isolated telephone paging interface as well as electronically balanced low-Z mic input and line level input for 
use with a tuner, CD player, tape, etc. The mixer also contains bass and treble control as well as power on and 

signal presence indicators. A master volume control adjusts the overall level. The power amplifier will produce 

40-Watts.

Installation

A. Ventilation

As with any power amplifier, this unit requires proper ventilation for safe use as well as its own long-term 
reliability. The DS1092 requires a free flow of cooling air on all sides as well as the top and bottom. Never 
place articles such as books, etc. on top of the unit or against its sides. Never operate the unit on a soft 
surface such as carpeting, etc. that may effect airflow on the bottom of the unit. Never operate the unit 
near a heat vent or other heat-generating devices. The power amplifier relies upon its ability to get cool air.

B. Connecting & using the masking generator

1. 

Connect a 40 Watt (or less) load to the 70 Volt output or an 8 ohm load (or greater) to the 8 ohm 
output. Only one output may be used at a time. Don’t attempt to use the 70 Volt and 8 ohm outputs 

simultaneously.

2.  Turn all front panel controls to “0”.
3. 

Connect the DS1092 to a nominal 120 Volt 50-60 Hz source.

4.  The green power LED should now be lit.
5.  Set the Pink / White switch to the desired position.
6. 

Set the Low Pass and Masking controls to 3 and adjust volume to approximately 47 dBA, generally 

around 5.

7.  Gradually increase the Volume control. The yellow Signal LED should come on at between 2 and 4 on 

the volume control setting.