page 10
Installation and Operation Guide
Qt X Sound Masking System
Figure 8.
Typical privacy light panel connection
Panel Connections
(continued)
Privacy Lights Outputs
Two ports are provided to interface with privacy lights panels. They may be
designated to 2 different zones and should be home run from the controller to
the privacy panel. See Figures 7-8.
5 VDC outputs are available to indicate sound masking is active on a specific
zone as indicated by privacy lights. The functionality is as follows;
Privacy 1 - Connect the positive lead of a privacy sign to Pin 1 and GND (observe
polarity). Select a zone in the Zone Name dialog to associate the Privacy light to
a specific sound masking zone. When the zone is active (above -20dB in level)
the privacy light will illuminate.
Privacy 2 – Same behavior as indicated above with privacy sign connections to
Pin 2 and GND.
Figure 7.
Privacy lights connection / wiring
Contact Connections (source)
Follow the instructions provided with the privacy sign to make sure that the unit
is connected to the controller inputs correctly.
+ –
SPEECH PRIVACY PROTECTION
SPEECH PRIVACY PROTECTION
Next Generation Sound Masking
Next Generation Sound Masking