background image

11

• A skilled licensed electrician must be asked for any repair of the     

electric system. Strictly perform electric connections in compliance 

with the applicable rules of the country.

• Strictly use original parts. DANGER : the manufactuer is not respon-

sible for damages/injuries caused by the use of non original spare 

parts.

• Repairs of any other part of the machine may be strictly performed 

by the manufacturer.

5.1. Placement 

• Install the splitter on a 60 - 75 cm high table, to obtain an  

 

  ergonomic and safe working position.  

• Provide a flat, clear working surface and due, proper illumination   

   of the room. 

 

• Never operate a log-splitter near diesel oil, fuel, gasoline or other    

   flamable materials.  

 • The working area around the machine must be kept as clear as  

 

   possible from surrounding obstacles and slippery foundation  

 

   floors should be duly treated.

5.2. Start-up

• Before you start working with the log-splitter: 

   - inspect the conditions of the connection lines and     

   - inspect the machine to detect eventual visible damages   

   - check the correct tightness of all screws 

   - check the hydraulic system for eventual leaks

• Check the general conditions and make sure that the splitter is duly 

assembled with all its parts and fittings. 

• Hand guards installation is mandatory for safety reasons. Working 

without will impair other parties‘ liabilities in the event of a personal 

injury.

 

5.3. Electric specs

 

                                       • Check the compliance of your network power specs with the ones    

      

of the identification label and plug the machine to a compliant  

 

      

approved socket. 

 

 

 

• Strictly use extension cable of the correct section. 

 

 

 

 

• Provide connection to the network by ways of a 30 mA RCD  

 

      

(residual current device) 

 

 

• Required domestic overload safety is 8.5 A.

5.  OPERATION AND SETUP

Содержание THS 5

Страница 1: ...ting the rewood maschine HYDRAULIC LOG SPLITTER THS 5 S dharzer Maschinenbau GmbH Helmestra e 94 99734 Nordhausen Harz Receptionist 03631 6297 0 111 Internet www bgu maschinen de e mail info bgu masch...

Страница 2: ...11 5 4 Hydraulic specs 12 5 5 Operating your log splitter 12 5 6 Splitting tips 12 5 7 Splitting cycle 13 5 8 End of the work 13 6 Repairs and maintenance 14 6 1 Ordinary periodic maintenance 14 6 2 S...

Страница 3: ...the problem or functional trouble is not listed in the troubleshooting chart contained in this manual ask your Au thorized Service Centre for service When you have checked all the possible causes lis...

Страница 4: ...ransport damages must be noti ed within latest 2 days from delivery Therefore delivery must be collected and inspected with in this term Later claims shall be disregarded In case of assumed but not vi...

Страница 5: ...ERVIEW Push block Control push button Lateral log guides Log splitter main parts and controls Cylinder cover Splitter wedge Oil dipper rod Hand guard Electric motor 2 hands control levers Piston rod A...

Страница 6: ...nt or loss of hearing wear a suitable protective device such as ear plugs or goggles 5 Operation safety label It is strictly forbidden to run the machine without its safeties and pro tections to bypas...

Страница 7: ...Identi cation label with BGU Maschinen logo The following warning symbols are used in this ma nual with this meaning WARNING This symbol precedes a general CAUTION or WARNING statement Where you see...

Страница 8: ...t or wood ash for this purpose Make sure that the equipment stands on a safe stable foundation 4 1 General safety rules Following precautions must be taken at all times Only skilled competent persons...

Страница 9: ...lcohol or other medicaments Keep your workplace tidy and as clear as possible from surrounding obstacles to avoid dangerous situations for your own safety Due and proper illumination of the working si...

Страница 10: ...anty claims in which case the manufacturer will not be responsible for custo mers claims or resulting damages and or injuries 4 4 Electric safety Use IEC power cords 60245 H 07 RN F with at least 2 5...

Страница 11: ...rom surrounding obstacles and slippery foundation oors should be duly treated 5 2 Start up Before you start working with the log splitter inspect the conditions of the connection lines and inspect the...

Страница 12: ...in the machine Then press both control levers down at the same time to operate the ma chine g 1 As you operate both handles concurrently down the push block starts to slide and feed the log completel...

Страница 13: ...s that may damage the machine In this case stop the machine Fig 4 turn the chunk around and try again Clearing logs sticking to the wedge Clear both control buttons and control handle to let the push...

Страница 14: ...ed using a ne grin ding le Makes sure to remode chips and dust before using the splitter again see gure 5 Fig 5 6 3 Hydraulic oil specs Periodically check the oil level inside the hydraulic oil tank W...

Страница 15: ...aking sure that the gasket is tightly in place Worn out gasket should be replaced before starting to work again Secure the dipper rod tightly in place avoiding to apply excessive torque on the screw a...

Страница 16: ...ahead of discarding Certain components need deactivation and dismantling in order to assure that no furtheru se is made by other parties and that no worn out parts are recycledfor other applications...

Страница 17: ...one tted with unau thorized modi cation Any modi cations to your machine can cause personal injuries and will void your Warranty Consumable parts with a prescribed life i e pulleys tools and variousau...

Страница 18: ...ea sure THS 5 Log capacity mm 530 Min log diameter mm 50 Max log diameter mm 250 Splitting power t 5 Motor power P1 kW 1 5 Rated voltage V 230 50 Hz Motor speed 1 min 2820 Rated current A 8 5 Machine...

Страница 19: ...r discolora tion Let the manufacturer x eventual leasks Check the oil level and top up if required Contact the manufac turer if the problems remains or occurs frequently Use admissible connections Pus...

Страница 20: ...Seal for air bleed screw 5 Lateral log guide 6 Upper plastic pad 7 Lower plastic pad 8 Connectors 9 Control handle w hand guard 10 Wheels 11 Cylinder Pos Nr Description 12 Piston rod 13 Stop rod 14 Mo...

Страница 21: ...further declare that this equipment was duly desi gnedand manufactured in accordance with the actual European Safety and Health Standards settled by therelevant EEC directives as well as the latest e...

Страница 22: ...22...

Страница 23: ...23...

Страница 24: ...harzer Maschinenbau GmbH Helmestra e 94 99734 Nordhausen Harz Service Tel 49 0 3631 6297 104 Fax 49 0 3631 6297 111 Internet www bgu maschinen de Subject to change without notice Form 2008 04 12 2006...

Отзывы: