6
Setting the Temperature Controller Parameters (See Figure 2)
Single Ramp
1.
Turn power on.
2.
Turn positioning beam on and position heater.
3.
Set controller parameters
4.
Hold the
button for 1-2 seconds
a.
Set rp1 (ramp time) in minutes
Press
b.
Set ct1 (cure temp) in degrees
Press
c.
Set hd1 (hold time) in minutes
Press
d.
Set rp2 = 0 (this disables 2
nd
ramp)
Press
5.
Press the
to exit setup menu
6.
Set auxiliary heater off or on
7.
Press the cycle start
Double Ramp
1.
Turn power on.
2.
Turn positioning beam on and position heater.
3.
Set controller parameters
4.
Hold the
button for 1-2 seconds
a. Set rp1 (ramp time) in minutes
Press
b. Set ct1 (cure temp) in degrees
Press
c. Set hd1 (hold time) in minutes
Press
d. Set rp2 (2
nd
ramp time) in minutes
Press
e.
Set ct2 (2
nd
cure temp) in degrees
Press
f.
Set hd2 (2
nd
hold time) in minutes
Press
5. Press the
to exit the setup menu
6. Set auxiliary heater off or on
7. Press cycle start
Figure 2
Содержание AutoCure 5000
Страница 1: ...January 2016 AutoCure 5000 Portable Repair Arm Assembly and Operating Manual AC5 2116 380...
Страница 18: ...18 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 19: ...19 Mechanical Drawings and Parts Lists Pyrometer...
Страница 20: ...20 CAUTION...
Страница 22: ...22...
Страница 24: ...24...
Страница 26: ...26 Heater Head Assembly ACH5 2116...
Страница 36: ...36 F DETAIL F POSITION LEVER CAUTION REF ABOVE ITEM CENTERED AC 59981 68 62 44 47 38 62 51 49 42 19...
Страница 40: ...40 SECTION J J SCALE 1 8 K DETAIL K SCALE 1 4 88 53 89 64 63 83 86 16 17...
Страница 45: ...45 ACH5 2116 Lamp Wiring Schematic...