Maintenance
The AutoCure™5000 will require some basic maintenance when used on a regular basis. Failure to do so may
degrade the performance of the unit.
Disconnect main power at the source before performing any maintenance procedures.
Pivot Points
1.
Single head units have three (3) castle nut/spring combinations and two (2) shoulder bolts with Nylock nuts.
If pivot points become loose, heater positioning will not be maintained. Check these points monthly.
2.
Dual head units have seven (7) castle nut/spring combinations and two (2) shoulder bolts with Nylock nuts. If
pivot points become loose, heater positioning will not be maintained. Check these points monthly.
3.
To adjust spring tension; remove cotter pin, tighten castle nut (usually one or two notches) and replace cotter
pin through bolt.
Lamps, Reflectors and Heat Sensor (Pyrometer) Lens
Clean with soft cloth and alcohol monthly. Heat sensor accuracy is dependent on a clean
lens.
Tension Spring/
Castle Nut
Nylock Nut
Tension Spring/
Castle Nut (4)
(under heater skin)
Tension Spring/
Castle Nut (2)
Tension Spring/
Castle Nut (2)
Single Head
Dual Head
Pyrometer
Содержание AutoCure 5000
Страница 1: ...January 2016 AutoCure 5000 Portable Repair Arm Assembly and Operating Manual AC5 2116 380...
Страница 18: ...18 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 19: ...19 Mechanical Drawings and Parts Lists Pyrometer...
Страница 20: ...20 CAUTION...
Страница 22: ...22...
Страница 24: ...24...
Страница 26: ...26 Heater Head Assembly ACH5 2116...
Страница 36: ...36 F DETAIL F POSITION LEVER CAUTION REF ABOVE ITEM CENTERED AC 59981 68 62 44 47 38 62 51 49 42 19...
Страница 40: ...40 SECTION J J SCALE 1 8 K DETAIL K SCALE 1 4 88 53 89 64 63 83 86 16 17...
Страница 45: ...45 ACH5 2116 Lamp Wiring Schematic...