Logic
Definition
Default
Cross
out
setting
used
Optional extras
IBL OPEN
Block pulses during
opening
0
0
Pulse from inputs configured as Start E, Start I, Ped has effect during opening.
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during opening.
|IBL TCA
Block pulses during
TCA
0
0
Pulse from inputs configured as Start E, Start I, Ped has effect during TCA pause.
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during TCA pause.
IBL CLOSE
Block pulses during
closing
0
0
Pulse from inputs configured as Start E, Start I, Ped has effect during closing.
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during closing.
OPEN IN OTHER
DIRECT.
Open in other
direction
0
0
Standard operating mode
1
Opens in other direction to standard operating mode
SAFE 1
Configuration of
safety input SAFE 1.
72
0
0
Input configured as Phot (photocell).
1
Input configured as Phot test (tested photocell).
2
Input configured as Phot op (photocell active during opening only).
3
Input configured as Phot op test (tested photocell active during opening only).
SAFE 2
Configuration of
safety input SAFE 2.
74
6
4
Input configured as Phot cl (photocell active during closing only).
5
Input configured as Phot cl test (tested photocell active during closing only).
6
Input configured as Bar, safety edge.
7
Input configured as Bar, tested safety edge.
8
Input configured as Bar 8k2.
9
Input configured as Bar OP, safety edge with inversion active only while opening. If while closing, the
movement stops.
10
Input configured as Bar OP TEST, safety edge tested with inversion active only while opening. If while
closing, the movement stops.
11
Input configured as Bar OP 8k2, safety edge with inversion active only while opening. If while closing,
the movement stops.
12
Input configured as Bar CL, safety edge with inversion active only while closing. If while opening, the
movement stops.
13
Input configured as Bar CL TEST, safety edge tested with inversion active only while closing. If while
opening, the movement stops.
14
Input configured as Bar CL 8k2, safety edge with inversion active only while closing. If while opening,
the movement stops.
SAFE 3
Configuration of
safety input SAFE 3.
77
2
0
Input configured as Phot (photocell).
1
Input configured as Phot test (tested photocell).
2
Input configured as Phot op (photocell active during opening only).
3
Input configured as Phot op test (tested photocell active during opening only).
4
Input configured as Phot cl (photocell active during closing only).
5
Input configured as Phot cl test (tested photocell active during closing only).
6
Input configured as Bar, safety edge.
7
Input configured as Bar, tested safety edge.
8
NOT AVAILABLE
9
Input configured as Bar OP, safety edge with inversion active only while opening. If while closing, the
movement stops.
10
Input configured as Bar OP TEST, safety edge tested with inversion active only while opening. If while
closing, the movement stops.
11
NOT AVAILABLE
12
Input configured as Bar CL, safety edge with inversion active only while closing. If while opening, the
movement stops.
13
Input configured as Bar CL TEST, safety edge tested with inversion active only while closing. If while
opening, the movement stops.
IC 1
Configuration of
command input IC 1.
61
0
0
Input configured as Start E.
1
Input configured as Start I.
IC 2
Configuration of
command input IC 2.
62
4
2
Input configured as Open.
3
Input configured as Close.
IC 3
Configuration of
command input IC 3.
64
2
4
Input configured as Ped.
5
Input configured as Timer.
IC 4
Configuration of
command input IC 4.
65
3
6
Input configured as Timer Pedestrian.