background image

346

LEO

LEO

Thank you for buying this product, our company is sure that you will be more
than satisfied with its performance.
This product is supplied with an 

Instruction Manual

 which should be read

carefully  as  it  provides  important  information  about  safety,  installation,
operation and maintenance.
This  product  complies  with  recognised  technical  standards  and  safety
regulations. We declare that it is in conformity with the following European
Directives: 89/336/EEC, 73/23/EEC and subsequent amendments.

1) GENERAL SAFETY
WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.

The

Warnings

  leaflet  and 

Instruction  booklet

  supplied  with  this

product should be read carefully as they provide important information
about safety, installation, use and maintenance.

Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children

s reach.

Keep  the  instructions  together  with  the  technical  brochure  for  future
reference.

This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.

The Company declines all responsibility for any consequences resulting
from improper use of the product, or use which is different from that
expected and specified in the present documentation.

Do not install the product in explosive atmosphere.

The  construction  components  of  this  product  must  comply  with  the
following  European  Directives:  89/336/CEE,  73/23/EEC,  98/37/EEC
and subsequent amendments. As for all non-EEC countries, the above-
mentioned standards as well as the current national standards should
be respected in order to achieve a good safety level.

The Company declines all responsibility for any consequences resulting
from  failure  to  observe  Good  Technical  Practice  when  constructing
closing structures (door, gates etc.), as well as from any deformation
which might occur during use.

The installation must comply with the provisions set out by the following
European  Directives:  89/336/CEE,  73/23/EEC,  98/37/EEC  and
subsequent amendments.

Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.

Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3mm.

Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.

Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.

Fit  all  the  safety  devices  (photocells,  electric  edges  etc.)  which  are
needed  to  protect  the  area  from  any  danger  caused  by  squashing,
conveying and shearing.

Position at least one luminous signal indication device (blinker) where
it can be easily seen, and fix a Warning sign to the structure.

The Company declines all responsibility with respect to the automation
safety and correct operation when other manufacturers

 components

are used.

Only use original parts for any maintenance or repair operation.

Do not modify the automation components, unless explicitly authorised
by the company.

Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.

Do  not  allow  persons  or  children  to  remain  in  the  automation
operation area.

Keep radio control or other control devices out of children

s reach, in

order to avoid unintentional automation activation.

The  user  must  avoid  any  attempt  to  carry  out  work  or  repair  on  the
automation  system,  and  always  request  the  assistance  of  qualified
personnel.

Anything which is not expressly provided for in the present instructions,
is not allowed.

2) GENERAL OUTLINE

The

LEO

  control  panel  is  supplied  by  the  manufacturer  with  standard

setting. Any alteration must be set by means of the incorporated display
programmer or by means of UNIPRO. The Control unit completely supports
the EELINK protocol, including the programmer self-supply from the control
unit.

It is available in two versions: one for external installation, inside the SD
box, the other fitted and pre-wired inside the ICARO controller.
Its main characteristics are:
-

Electronic torque setting

-

Adjustable electrodynamic braking

-

Closing / opening limit-switch inputs

-

Separate inputs for safety devices

-

Clock input

-

Serial protocol connection input

-

Incorporated radio receiver

The board is provided with a terminal board which can be pulled out for
easier maintenance or replacement. The board is supplied with a series of
pre-wired jumpers to facilitate the installer

s work.

The jumpers relate to the following terminals: 21-23, 21-24 and 21-30. If the
above-mentioned terminals are in use,  remove their respective jumpers.

3) TECHNICAL SPECIFICATIONS

Power supply: ................................................................ 230V

±

10% 50Hz*

Mains/low voltage insulation: ....................................... > 2MOhm 500Vdc
Dielectric strength: ..................... mains/low voltage 3750Vac for 1 minute
Motor output current: .................................................................... 1.5Amax
Maximum motor power: ...................................................................  750W
Supply to accessories: ................................... 24Vac (1A max absorption)
Gate-open warning light: ................................................... 24Vac 3W max
Blinker: ............................................................................... 230V 40W max
Dimensions: ............................................................................. see figure 1
Fuses: ...................................................................................... see figure 2
(* other voltages available on request)

4) TERMINAL BOARD CONNECTIONS (Fig.3)

WARNING

During the wiring and installation operations,  refer to the

current standards as well as principles of good technical practice.

The cables must be tied by additional fastening next to the terminals, by
means of clips for example.
All the operator wiring operations must be carried out by qualified personnel.

JP1

1

GND terminal

2-3

Single-phase mains supply 230V

±

10% 50Hz (2=N) (3=L)

JP2

4-5

Blinker connection (mains voltage) 40W Max.

6-7-8-9

Motor connection:
6 operation 1 + capacitor
7 common (blue)
8 operation 2
9 capacitor

JP3

10-11

Output 24V~ 1A max 

 power supply for photocells or other

devices.

12-13

Gate-open warning light output (24V 3W max)

JP5

Encoder connection

WARNING!

The maximum length of the connection cable of

the encoder should not exceed 3.00 mt.

JP8

21-22

Open-Close button (N.O. Start), key selector.

21-23

Block button (N.C. Stop). If not used, leave jumped.

21-24

Photocell input (N.C.). If not used, leave jumped.

21-25

Opening  limit  switch  connection  (N.C.  SWO).  If  not  used,
leave jumped.

21-26

Closing limit switch connection (N.C. SWC). If not used, leave
jumped.

21-27

Pedestrian button connection (N.O. Ped)

21-28

Open-Button connection (N.O. Open)

21-29

Close-Button connection (N.O. Close)

21-30

Rubber edge connection (N.C.). If not used, leave jumped.

21-31

Timer input connection (N.O.). If the contact is open the leaves
close and the gate is ready for normal operation. If the contact
is closed (N.C.), the leaves open and remain open until the
contact is opened.

JP9

34

TX1 serial output

35

TX2 serial output

36

RX1 serial imput

37

RX2 serial input

38-39

Antenna input for snap-in radio receiver board (38 signal - 39
braid). Cable RG58

40-41

Second radio channel output of twin-channel receiver board

D811327_03

CONTROL UNITS

CONTROL UNITS

Содержание LEO

Страница 1: ...LEO CONTROL UNIT FOR ICARO D80000 00 00 99 Vers 00 ...

Страница 2: ... case of emergency Do not allow persons or children to remain in the automation operation area Keep radio control or other control devices out of children s reach in order to avoid unintentional automation activation The user must avoid any attempt to carry out work or repair on the automation system and always request the assistance of qualified personnel Anything which is not expressly provided ...

Страница 3: ...rque value between 1 and 99 5 Closing torque cls torque 50 Set the motor closing torque value between 1 and 99 6 Brake Brake 0 Set the required brake value between 0 and 99 compatibly with the weight of the gate and the existing stresses 7 Zone zone 0 Set the zone number between a minimum value of 0 and a maximum value of 127 See paragraph 7 on Serial connection 6 2 Logic Menu logic TCA tca ON ON ...

Страница 4: ... panel allows several automation units to be connected in a centralised way by means of appropriate serial inputs and outputs This makes it possible to use one single command to open and close all the automation units connected Following the diagram in Fig 5 proceed to connecting all the LEO control panels exclusively using a telephone type line Should a telephone cable with more than one pair be ...

Страница 5: ...6m TCA value expressed in seconds default 40 40s min 1 1s max 180 180s Encoder Ð value expressed in default 80 min 1 max 99 Opening torque Ð value expressed in default 50 min 1 max 99 Closing torque Ð value expressed in default 50 min 0 max 99 Brake Ð value expressed in default 0 min 1 max 99 Zone Ð numerical value default 0 min 0 max 127 Simultaneously press the and keys Simultaneous pressure of ...

Страница 6: ...o r s t a n d i n g w i t h i n t h e automation operating range RADIO MENU ADD Allows you to add one key of a radio control device to the receiver memory after storage it displays a m e s s a g e s h o w i n g t h e r e c e i v e r n u m b e r i n t h e memory location from 01 to 64 NOTE When using transmitters with two or more channels the first push button which has been stored is associated to...

Страница 7: ... ANT SWC PED OPEN CLOSE TIMER COSTA II CH R 24 V PHOT SW0 10 11 12 13 JP3 ANT SHIELD 24 V 40W max 34 35 36 37 38 39 40 41 JP9 4 5 6 7 8 9 21 22 23 24 25 26 27 28 29 30 31 34 35 36 37 38 39 40 41 OK Enter 8888 236 194 100 LEO SD 8888 24V 3W max SCA TX1 RX1 RX2 TX2 Fig 5 10 11 12 13 6 3 AF 0 315 AT 2AT D811327_03 LEO LEO CONTROL UNITS CONTROL UNITS ...

Страница 8: ...x 250m UNIFLAT 8888 21 22 23 24 25 26 27 28 29 30 31 34 35 36 37 38 39 40 41 21 22 23 24 25 26 27 28 29 30 31 34 35 36 37 38 39 40 41 21 22 23 24 25 26 27 28 29 30 31 34 35 36 37 38 39 40 41 21 22 23 24 25 26 27 28 29 30 31 34 35 36 37 38 39 40 41 D811327_03 LEO LEO CONTROL UNITS CONTROL UNITS ...

Страница 9: ...4 35 36 37 38 39 40 41 10 11 12 13 5 AF 0 315 AT 2AT M2 SLAVE M1 MASTER FIG 6a FIG 6b LEO M1 MASTER 1 2 3 4 5 6 7 8 9 21 22 23 24 25 26 27 28 29 30 31 34 35 36 37 38 39 40 41 10 11 12 13 5 AF 0 315 AT 2AT LEO M2 SLAVE TCA OFF STOP SWO2 SWC2 CC2 NC PHOT NC NC NC NC NC NC D811327_03 LEO LEO CONTROL UNITS CONTROL UNITS ...

Отзывы: