Technical data
3-2
3.3
Electrical system, Optical and Mechanical Data
Power Supply Input
24 V DC (terminals 29 and 30)
100-240 V AC (terminals 16 and 17)
Power Supply Out for CFC4000
24 V DC
External fuse
max. 1 A, slow blow
Current supply for CFC3000
Current consumption, total
max. 0.2 A
max. 0.300 A at DC-supply
max. 0.050 A at 230 V AC supply
max. 0.115 A at 115 V AC supply
Power consumption
approx. 7.2W
Relay
SPDT
max. swichting voltage 250 V,
resistive load
max. switching current 1 A, resistive load
max. switching power 300 VA
Quantity Current outputs:
Current
3
0(4) to 20 mA
Interface:
USB
RS 485
read only
read and write
Signal Recorder
On SD-card (max. 32GB), requires approx.
100 MB per day.
Protection class
Standard housing
IP66-housing
IP 50
IP66
Protection
II
Mounting method
Terminal housing for DIN rail, 35 mm or
wall mounting
Ambient temperature
-20 °C to +70 °C
Dimensions
99.7 x 75 x 140 mm (heights incl. USB-cable)
Weight
Standard housing
IP66-Gehäuse
approx. 400 g
approx. 2.5 kg