WS2003 V1.69
19
...operation with a fieldbus
*The discrete
Weld on
input must also be on to enable welding.
Dual gun
INPUT from bus to timer
OUTPUT from timer to bus
Bit No. Function
Bit No. Function
0
START 1
0
End of stepper 2
1
START 2
1
End of stepper 1
2
START 3
2
End of count 2
3
START 4
3
End of count 1
4
2nd Stage
4
Contactor
5
Weld on*
5
Not ready
6
Reserved
6
Fault
7
Reserved
7
End of sequence (EOS)
8
Reset counter 1
8
Weld air valve 1 (WAV 1)
9
Reset stepper 1
9
Weld air valve 2 (WAV 2)
10
Retract 1
10
Retract air valve 1 (HAV 1)
11
Reset counter 2
11
Retract air valve 2 (HAV 2)
12
Reset stepper 2
12
Discrete input I10
13
Retract 2
13
Discrete input I11
14
Reserved
14
Discrete input I12
15
Reset fault
15
Discrete input I13
16
Program bit 1
16
Error code bit 1
17
Program bit 2
17
Error code bit 2
18
Program bit 4
18
Error code bit 4
19
Program bit 8
19
Error code bit 8
20
Program bit 16
20
Error code bit 16
21
Program bit 32
21
Error code bit 32
22
Reserved
22
Error code bit 64
23
Reserved
23
Error code bit 128
Map=1
Map=2
24
Discrete output Q01
24
Pressure bit 1
Discrete input I1
25
Discrete output Q02
25
Pressure bit 2
Discrete input I2
26
Discrete output Q03
26
Pressure bit 4
Discrete input I3
27
Discrete output Q04
27
Pressure bit 8
Discrete input I4
28
Discrete output Q05
28
Pressure bit 16
Discrete input I5
29
Discrete output Q06
29
Pressure bit 32
Discrete input I6
30
Discrete output Q07
30
Pressure bit 64
Discrete input I7
31
Discrete output Q08
31
Pressure bit 128 Discrete input I8
Single gun /Multi-gun
INPUT from bus to timer
OUTPUT from timer to bus
Bit No. Function
Bit No. Function
0
START 1
0
Prewarning
1
START 2
1
End of stepper
2
START 3
2
Reserved
3
START 4
3
End of count
4
2nd Stage
4
Contactor
5
Weld on*
5
Not ready
6
Reserved
6
Fault
7
Reserved
7
End of sequence (EOS)
8
Reset counter
8
Weld air valve 1 (WAV 1)
9
Reset stepper
9
Low force air valve (LFAV) / Motor
10
Retract 1 / Reset All
10
Retract air valve 1 (HAV 1)
11
Reserved
11
Reserved
12
Reserved
12
Discrete input I10
13
Reserved
13
Discrete input I11
14
Reserved
14
Discrete input I12
15
Reset fault
15
Discrete input I13
16
Program bit 1
16
Error code bit 1
17
Program bit 2
17
Error code bit 2
18
Program bit 4
18
Error code bit 4
19
Program bit 8
19
Error code bit 8
20
Program bit 16
20
Error code bit 16
21
Program bit 32
21
Error code bit 32
22
Reserved
22
Error code bit 64
23
Reserved
23
Error code bit 128
Map=1
Map=2
24
Discrete output Q01
24
Pressure bit 1
Discrete input I1
25
Discrete output Q02
25
Pressure bit 2
Discrete input I2
26
Discrete output Q03
26
Pressure bit 4
Discrete input I3
27
Discrete output Q04
27
Pressure bit 8
Discrete input I4
28
Discrete output Q05
28
Pressure bit 16
Discrete input I5
29
Discrete output Q06
29
Pressure bit 32
Discrete input I6
30
Discrete output Q07
30
Pressure bit 64
Discrete input I7
31
Discrete output Q08
31
Pressure bit 128 Discrete input I8