Bevi Standup v1.0 Скачать руководство пользователя страница 17

 

3. Dispense at least 3L of plain, still water into the bucket, discarding it 

periodically until the water flows clear.  

4. Remove the length of tube, reattach the outlet line, and dispense 

another liter or so of water through the machine to ensure a clean flow 
throughout. 

Testing Water

 

Test each type of water - still, sparkling, and each flavor - testing for the 
following: 

Cool temperature (it will not be fully chilled yet) 

Correct, noticeable, and enjoyable flavor 

Sufficient CO 

 concentration 

Consistent flow 

 
If any of these seem off, consult the Bevi Hardware Guide or contact Bevi 
Support at  [email protected] .   

Enter Incubation 

IMPORTANT NOTE: 

  

Incubation is a mandatory part of the installation 

process. Without it, the Bevi temperature will be too high to properly 
operate. Do not skip this step. 
 

1. Once all components are properly connected and water is flowing 

properly, close and lock the door of the Bevi.  

2. In the service panel, press the  Start Incubation  button on the Other tab 

at the bottom of the page.  

3. Select the incubation time. We recommend 3 hours, but it can be set 

lower if the carbonator has already been running for some time.  

4. A screensaver with a countdown will appear. If you need to exit the 

screensaver and return to the control panel, tap repeatedly between 
the hours and minutes on the screen. 

Bevi Support

 

Online:  partners.bevi.co 
Phone:  866-704-2384 

 

                                                   

© 2018 Bevi. All rights reserved.                                                   [email protected]

 

 

Содержание Standup v1.0

Страница 1: ...Bevi v1 0 Installation Guide Last Revision January 2019...

Страница 2: ...where it can be overseen by trained personnel The appliance must not be cleaned by a water jet For indoor use only 10 32 C 50 90 F Appliance shall not be installed in an area where a water jet could b...

Страница 3: ...Ice Bank Installing the Carbonator Attaching Water Lines Installing the CO2 Tank Installing Flavors Checking the Lines Initializing the Service Panel Connecting to the Internet Initial Stocking Creat...

Страница 4: ...the Partner Resource site at partners bevi co Bevi Components Bevi ships on a pallet that contains the internal components for the machine as well as the chassis For detailed information on each comp...

Страница 5: ...Flow Compensator and Line Filter Out ow Line with Pressure Regulator Pentek OR 3M Filter CO2 Regulator Drip Tray 2018 Bevi All rights reserved support bevi co...

Страница 6: ...use or smaller it will cause ow problems and machine damage Additionally the following components are not included with the unit by default but are necessary for install Flavor Concentrate Boxes 4 10...

Страница 7: ...hin 50 ft of the unit Electrical 110 120 VAC 60 Hz 9A max current draw GFCI protected 3 prong outlet Space At least 3 ventilation room behind the machine the Bevi is 22 deep Measuring Water Pressure I...

Страница 8: ...ut aside 2 Place the drip tray on the bottom of re ll station and slide into place 3 Plug the Bevi power adapter into back of Bevi then into power outlet do not turn on power switch yet 4 Screw the Wi...

Страница 9: ...r out ow line and pressure regulator to the outlet of the lter housing 10 Turn the power button on the back of the machine on to ensure power is working The tablet should turn on and the lights above...

Страница 10: ...bove 6 Doing so will cause the carbonator to freeze and can damage the unit Installing the Carbonator 1 Lock the wheels of the Bevi so they do not roll and lift the carbonator into the unit with the o...

Страница 11: ...e on the CO2 tank so gas begins to ow and ensure that the valve on the regulator is open pointing downwards 5 Ensure that the pressure on the top gauge the one closer to the CO2 tank reads 87 psi 6 ba...

Страница 12: ...and off the spout of the bag The old box can now be removed and discarded 5 Open a new box of avor concentrate by pressing in on the perforated area The label should be inspected to con rm avor number...

Страница 13: ...It should only take 30 seconds or so for the touchscreen to boot up Initializing the Service Panel The service panel can be accessed from the main tablet touchscreen To enter the panel 1 Press the Ing...

Страница 14: ...l Connecting to the Internet To connect to a network 1 Press the Change button on the top of the service panel 2 Select the appropriate connection type from the three options 2018 Bevi All rights rese...

Страница 15: ...ge and check that the internet is properly connected The icon on the left of the network eld should be green with a Connected tag and the connection type listed Initial Stocking Flavors For each avor...

Страница 16: ...en properly connected to the internet the page should update itself within a few minutes with the current inventory Final Steps Purging the Carbonator To ensure that the CO2 and water mix properly per...

Страница 17: ...Incubation IMPORTANT NOTE Incubation is a mandatory part of the installation process Without it the Bevi temperature will be too high to properly operate Do not skip this step 1 Once all components ar...

Страница 18: ...Email support bevi co 2018 Bevi All rights reserved support bevi co...

Отзывы: