40
16 What if there are problems?
If the scale detects and error when measuring, the following is displayed.
Display
Cause
Remedy
ERROR:_OVERLOAD
The maximum load capacity of 150 kg
was exceeded.
Do not load the unit with over 150 kg.
LOW_BATTERY
The batteries are almost empty.
Replace the batteries (see page 25
and 39).
MEMORY_FULL
30 measurements have been saved. Transfer the measurements to a PC,
see page 38.
ERROR:_CONTACT
The electrical resistance between the
electrodes and the sole of your foot is
too high (e.g. if you have tough cal-
luses).
Repeat the measurement barefoot. If
necessary, moisten the soles of your
feet slightly. If necessary, remove the
calluses from the soles of your feet.
ERROR:_DATA
The BIA measurement was success-
ful but the fat percentage is outside
the measurable range (less than 5 %
or greater than 50 %).
Repeat the measurement barefoot
or, if necessary, moisten the soles of
your feet slightly. If necessary, chan-
ge the level of activity that you have
set.
The batteries in the control unit are
completely empty.
Replace the batteries (see page 26).
No display
The batteries in the control unit are
not inserted correctly.
Check to ensure that the polarity is
correct (see page 26)
No measurement possible
Possible errors
Remedy
The control unit was not activated
before you stepped on the scale.
Switch on the control unit first before the measurement.
If necessary, wait 30 seconds, then repeat the meas-
urement.
Cordless connection between scale
and control unit is interrupted.
Reinsert the batteries for the scale and the control unit.
Maintain a larger distance from the following electro-
magnetic sources: high-voltage pylons, television or
wireless computer systems, fitness equipment, mobile
phones, weather stations.
The control unit is too far away from
the scale.
Reduce the distance between the scale and control unit;
maximum distance is 2 metres.
The batteries in the scale are flat or
incorrectly inserted.
Change the batteries (see page 26) and check that they
are inserted the correct way round.
Incorrect weight measurement
Possible errors
Remedy
The scale is not zeroed
correctly.
Before taking a measurement, activate the scale briefly with your
foot until the operating status indicator lights up.
Wait approximately
5 seconds
and repeat the measurement. For
your information: because you would normally step onto the scale
immediately, the scale saves the zero point when the scale is swit-
ched off (when the operating status indicator goes out).
Scale is on carpeting.
Place the scale on a level and solid surface.
Stand with your feet as far apart as possible without tipping the
scales.
www.TopSport.com.ua