Parameters Function
Note
520
Centre the pallet
This values determines the distance for
half a revolution of the motor. If the
motor moves by one pulse (half a revo-
lution of the motor), the value multiplied
by 0.1 is entered.
524
Stretch carriage
This values determines the distance for
half a revolution of the motor. If the
motor moves by one pulse (half a revo-
lution of the motor), the value multiplied
by 0.1 is entered.
526
Stretch sled
This values determines the distance for
half a revolution of the motor. If the
motor moves by one pulse (half a revo-
lution of the motor), the value multiplied
by 0.1 is entered.
532 Conveyor
under
stretch
hood
This values determines the distance for
half a revolution of the motor. If the
motor moves by one pulse (half a revo-
lution of the motor), the value multiplied
by 0.1 is entered.
534
Crimping
This values determines the distance for
half a revolution of the motor. If the
motor moves by one pulse (half a revo-
lution of the motor), the value multiplied
by 0.1 is entered.
Status display
The control status of the inputs, outputs, flags and data can be displayed with
the help of the status display.
The words to be displayed are entered in the input fields for inputs, outputs and
flags. Then the status of the respective word is displayed in binary form in the
display field. The bits of the corresponding word are displayed from the right to
the left. The smallest bit is on the right.
The data are entered as words. The status is displayed in a decimal and binary
form.