Bettis P/N 126858
Revision "F"
Page 4 of 15
3.1.2.2 Remove the bleed plugs from the following locations:
3.1.2.2.1
G Series Actuators remove o-ring plug from the top of the outer
and inner end caps.
3.1.2.2.2
T Series Actuators remove pipe plugs from the top area located on
the outer and inner end of the hydraulic override cylinder.
3.1.2.2.3
HD Series Actuators remove pipe plug from the top area on the
outer end of the hydraulic override cylinder and the cylinder
adapter.
3.1.2.3 Disconnect the pump hose from the reservoir fitting, located close to the reservoir
upper end cap (10-10), and connect the pump motor to the pump hose.
NOTE: The M11 pump handle should be in the up position.
3.1.2.4 Place the M11 pump selector knob in the “Auto” position.
NOTE: The pressure pump should not exceed 10 to 20 psi when force filling the M11
hydraulic system.
3.1.2.5 Start pumping the hydraulic fluid into the system with the pump motor.
3.1.2.6 When hydraulic fluid appears at the vacant bleed plug port hole located in the
inboard area of the hydraulic override cylinder install pipe plug into the vacant port
hole. NOTE: Use pipe dope on the bleed pipe plug.
3.1.2.7 When hydraulic fluid appears at the vacant bleed plug port hole located in the
outboard area of the hydraulic override cylinder stop the pump motor and install
pipe plug into the vacant port hole. NOTE: Use pipe dope on the bleed pipe plug.
3.1.2.8 Disconnect the pump motor from the M11 pump hose.
3.1.2.9 Connect the M11 pump hose to the fitting on the reservoir outer end cap (10-10).
3.1.2.10 Remove the breather (10-140) from the top of the reservoir upper end cap (10-10).
3.1.2.11 Fill reservoir to 1-1/2 inches from top of reservoir end cap (10-10). Note: Add fluid
to the reservoir through the open port left vacant in step 3.1.2.10.
3.1.2.12 Apply pipe dope to breather (10-140) threads and install into the port in top of the
reservoir inner end cap (10-10).
3.1.2.13
Return the M11 pump selector knob to the “Auto” position. With the M11 selector knob in
the “Auto” position the actuator is ready for service.
3.1.3
REFILLING METHOD NUMBER 2. - Refilling the M11 Manual Hydraulic Override System
without using a pump motor.
3.1.3.1 Remove breather (10-140) from the top of the reservoir end cap (10-10).