19.
Insert the new membrane into the housing.
20.
Replace the Upper End-Cap, tightening with the tee-handle tool (
do not
over tighten
).
21.
Re-tape the 3/8" x 1/4" Fast-N-Tite with about 4 wraps of Telflon tape.
22.
Insert the 3/8" Blue Product Tubing into the 3/8" x 1/4" Fast-N-Tite.
AFTER REPLACEMENT
23.
After installation of all membranes, the RO should be started and the Product Water flushed
to drain for a
minimum of 2 hours.