Страница 2: ... for you Please familiarize yourself with this manual and the operation of the unit After a few easy steps you ll find that daily disinfecting of your CPAP equipment has never been easier This unique process eliminates bacteria mold viruses and other pathogens It does all this by using gaseous activated oxygen alone no need for liquid disinfectors or messy preparations Please feel free to contact ...

Страница 3: ...ecifications 4 3 Included with your SoClean 5 4 Important Supplies 6 5 Getting Started 7 6 Your SoClean Timer Display 10 7 Using your SoClean 14 8 Care and Maintenance for your SoClean 16 9 FAQ 17 10 Classification Symbols Tables 18 Contents ...

Страница 4: ... unit and is intended to be used in the home and professional healthcare facility A patient who uses Continuous Positive Airway Pressure CPAP for Obstructive Sleep Apnea OSA treatment can use the SoClean to have a daily automated disinfector when one fails to follow daily cleaning procedures or wants the added benefit of a thorough disinfecting in addition to daily cleaning The SoClean is designed...

Страница 5: ...ncluded with your SoClean Removable hose slot plug installed SoClean check valve assembly with injection fitting and hose installed SoClean filter cartridge installed AC power adapter Neutralizing pre wash ...

Страница 6: ...ge installed This filter converts activated oxygen back into normal oxygen Replace every 6 months Neutralizing Pre Wash Fragrance free hypoallergenic cleaning solution The pre wash neutralizes any pre existing odors from detergents and removes any residue from the manufacturing process that could react with activated oxygen Use the pre wash whenever you hand wash your CPAP equipment Use either the...

Страница 7: ...ied for hand washing your CPAP equipment only 2 Installing the Injection Fitting With humidifier Disconnect your CPAP hose from your CPAP machine Position the injection fitting onto the port of your reservoir allowing the smaller hose to enter into and rest on or near the bottom of the reservoir If necessary trim the injection hose if to fit in the reservoir Note If you keep water in the reservoir...

Страница 8: ...humidifier remove the short length of black hose from the inside of the injection fitting by pulling it straight off and then attach the fitting directly to your CPAP machine Reconnect your CPAP hose to end of the injection fitting Note You do not need to disconnect the injection fitting to use your CPAP You may leave the SoClean connected to your CPAP Depending on the style of your reservoir you ...

Страница 9: ...9 Getting Started 3 Power Up Plug your AC adapter into the back of the SoClean and then into a wall outlet Proceed to set your timer ...

Страница 10: ...ime You can easily change these settings by following the steps on the next page If you unplug the SoClean or experience a power loss you will need to reset the current time only The disinfecting settings will remain saved Your SoClean Timer Display Clock Set Disinfecting Cycle Set Current Time Cycle Start Time Disinfecting Cycle Indicator Light Length of Cycle Manual Control Decrease Increase ...

Страница 11: ...ing the Run Time and Duration Press the button Press the min or plusbutton to decrease or increase the number of minutes of your run time Note A run time of 5 to 10 minutes should be enough to completely disinfect your equipment Set Current Time Set Current Time Set Current Time Set Current Time Set Current Time Set Run Time in minutes Set Run Time in minutes Set Run Time in minutes Set Current Ti...

Страница 12: ...e button The SoClean will then operate according to your preset run time Your timer settings will not be affected As with your normal disinfecting procedure wait for the green light before removing your mask 24 Hour Clock If you prefer your clock to display in the 24 hour format military time press the minand clocbuttons You will then be prompted to choose either the 12 or 24 hour format Press the...

Страница 13: ...sfully completed The lighted display will turn off once the lid is lifted Display Messages Hose not present Cycle will not run This message displays during the manual mode when there is no mask hose in the SoClean the lid is not properly closed or the hose slot plug is missing or improperly seated Order filter kit This message displays after approximately 6 months of use as a reminder to order a r...

Страница 14: ... setup using your SoClean unit is extremely easy You will not need to disassemble any components to disinfect you equipment daily 1 Open the lid 2 Install the removable hose slot plug into one open slot Using Your SoClean ...

Страница 15: ...an will never operate without the mask and hose present in the securely closed chamber Additionally the SoClean will not operate if the hose slot plug is missing or improperly seated Important Even though the actual run time of the SoClean may only be 5 to 10 minutes it is necessary to let the mask remain in the closed chamber for at least 2 more hours After that period the cycle indicator light w...

Страница 16: ...ly and filter cartridge should be replaced every 6 months A reminder message on the display will appear after approximately 6 months depending upon usage Visit www BetterRestSolutions com or an authorized distributor to purchase a Cartridge Filter Kit Cartridge Filter REPLACE EVERY 6 MONTHS Check Valve Assembly REPLACE EVERY 6 MONTHS ...

Страница 17: ... complete Please wait until the light shines green to remove your CPAP equipment from the SoClean chamber see page 13 FAQ 6 What if my indicator light is not shining after a scheduled cleaning time This would indicate that the SoClean did not carry out its scheduled disinfecting Common reasons for this are that the lid was not securely closed there was no mask in the chamber at cleaning time or th...

Страница 18: ...ctor dB dB uV Indicator Limit 0 47405 2 5 19 9 22 4 24 4 PASS 47 0 48193 3 19 9 23 23 5 PASS 47 0 48718 2 3 19 9 22 2 24 1 PASS 46 0 48928 3 19 9 22 9 23 4 PASS 46 0 49694 1 8 19 9 21 8 24 3 PASS 46 0 50266 1 6 19 9 21 6 24 4 PASS 46 Chomerics Test Services Conducted Emissions Class B 150kHz 30 MHz 9kHz Resolution Bandwidth FCC Part 15 Subpart B Class B Neutral Line Quasi Peak Frequency Hot Line C...

Страница 19: ...ection AVG Margin dB Pass Fail Class B MHz AVG dB Factor dB dB uV Indicator Limit 0 47583 4 2 19 9 24 2 22 5 PASS 47 0 47597 4 5 19 9 24 4 22 2 PASS 47 0 48591 2 8 19 9 22 8 23 6 PASS 46 0 49005 2 9 19 9 22 9 23 4 PASS 46 0 49005 2 9 19 9 22 9 23 4 PASS 46 0 4934 2 6 19 9 22 6 23 6 PASS 46 Chomerics Test Services Conducted Emissions 150kHz 30MHz 9kHz Resolution Bandwidth FCC Part 15 Subpart B Clas...

Страница 20: ......

Страница 21: ...olutions com is a division of Inceptus Inc SoCleanTM is a trademark of Inceptus Inc Uxbridge MA U S A 01569 2001 Rev E USER GUIDE JDI ELECTRONICS FACTORY Sima Industrial Zone Sima Village Changping Town Dongguan City Guangdong 523570 China Eumena Ltd Eumena Ltd c o Friedrich Schwab Business Park Dangan Galway Ireland Tel No 49 173 280 8345 EC REP ...