Connect the T valve connector to your current
water supply pipes. Ensure there are no leaks
or lose connections before commencing.
Insert the filter onto the T connector and then
attach the water hose to the filter and the
water hose connector on the side of the
intelligent seat as shown.
Insert the water outlet onto the T connector
and now secure all fittings, ensuring that
the water pipe, filter and water inlet are
securely fastened.
Before replacing the seat, turn on the water supply, the stop valve and the electrical
supply. After turning on the water and electrical supplies you
MUST
carry out the RCD
test, instructions for this are printed on the rear of the RCD, also carry out a leak check on
all water connections.
Your intelligent seat is now ready to be used.