13
1. CLEANING THE SQUEEGEE HOSE
Check the squeegee hose for blockage if the suction is insufficient and at peri-
odic intervals. To clean the hose:
A. Remove the hose end from the squeegee hose adapter.
B. Remove the other end of the hose from the recovery tank.
C. Wash the inside of the hose with clear water, spraying from the end that con-
nects to the tank.
D. Reinstall the hose.
WARNING: Do not wash the hose that goes from the vacuum unit to
the recovery tank. This will damage the vacuum motor!
2. CLEANING THE SOLUTION TANK AND SCREEN
A. Unscrew the cap on the solution tank.
B. Remove and clean the filter screen.
C. Unplug the solution quick disconnect at the front of the tank.
D. Using a screwdriver, remove the two screws holding the solution tank to the
frame.
E. Remove the solution tank by pushing it forwards and unhooking it from the
locking plate.
F. Rinse the tank with clear water.
G. Drain the tank.
H. Reinstall tank on the machine.
I. Reinstall the filter screen and the cap.
WARNING: Always wear gloves to protect yourself from contact
with hazardous chemicals.
WARNING: Disconnect the quick disconnect fitting before removing
the solution tank.
SCHEDULED MAINTENANCE
Содержание GENIE CE HD APS
Страница 18: ...18 SQUEEGEE SYSTEM PARTS DIAGRAM 6 3 4 13 14 12 11 5 18 1 7 10 8 8 18 15 16 5 9 5 17 2 9 ...
Страница 20: ...20 SQUEEGEE YOKE PARTS DIAGRAM 4 2 11 13 10 6 7 5 2 6 7 9 14 12 8 3 1 ...
Страница 24: ...24 SOLUTION AND RECOVERY TANKS PARTS DIAGRAM 10 17 8 19 9 11 19 1 18 12 14 15 5 3 7 20 4 2 13 21 22 6 16 ...
Страница 28: ...28 ELECTRIC SYSTEM PARTS DIAGRAM 2 6 4 3 5 3 7 10 2 9 1 8 ...
Страница 30: ...30 ELECTRICAL DIAGRAM ...
Страница 31: ...31 ...