13
OPERATION MANUAL AND INSTRUCTIONS
EN
Troubleshooting
Always disconnect air supply before checking the pneumatic tool for failures or cleaning it, and empty the magazine; this precaution
will prevent the pneumatic tool from being accidentally started.
FAILURES
POSSIBLE CAUSES
SOLUTIONS
Fixing part jammed
Fixing part loaded incorrectly.
Check that fixing machine has been correctly loaded
as follows:
1) Open the magazine (picture 3).
2) Release the safety trigger on the door side (picture
4).
3) Open the front door, and remove the jammed
staple or nail (picture 4).
4) Close the door. Make sure that the lever locks the
door safely.
5) Load the staples or nails, and check that they slide
easily.
6) Push the magazine as much as required to close
it fully
Connect air supply to fixing machine and operate it.
Unsuitably sized fixing part.
Check dimensions of fixing part by comparing them
with dimensions stated in TECHNICAL DATA table.
Bits of glue or wood powder in
magazine or guide.
Remove bits of glue or wood powder.
No fixing part is ejected
Low pressure in air supply
system.
− Check compressed air supply system.
− Check output pressure.
Fixing part cannot be fitted in
completely
Low pressure in air supply
system.
− Check compressed air supply system.
− Check output pressure.
Other failures
− Contact repair centre.
Periodically, depending on the frequency of use, clean the pneumatic tool. If any operation defects that cannot be dealt with
through the instructions should be shown, send the pneumatic tool to the repair centre.