ISTRUZIONI PER L’USO
I
OPERATION MANUAL AND INSTRUCTIONS
EN
Settings
- Checking calibration for electronic balances.
- Setting language.
- Setting date and time.
- Setting LCD – Updating files.
Oil cleaning and change must always be performed with warm transmission oil (>40 °C). Please follow the
manufacturer’s specifications. A proper diagnostic test should be used.
ANALYTICAL DESCRIPTION OF CYCLES
Automatic transmission.
After connecting the “PRESSURE” and “RETURN” pipes, as described in the section “Use – Preparation for use”, take the
following steps.
STEP 1
- Connect the station to the power supply mains and press the side switch. The display will show AUTOMATIC
TRANSMISSION. Press the key; the display will show the following:
- Press the key to set the required amount of solvent. If you are not going to feed any solvent into the car circuit, keep
the “0” setting. After the required amount of solvent has been set, press the key.
Make sure to have checked the compatibility of the solvent with the transmission.
- The cursor will automatically select “cleaning min.“. Press the key to set the required duration of the cleaning cycle. If you
are not going to perform any cleaning cycle, keep the “0” setting. After the required duration of the cleaning cycle has been set,
press the key. .
- The cursor will automatically select “oil lt.”. Press the key to set the total amount of oil in the automatic transmission
system to be changed. After the amount of oil has been set, press the key.
- If the data about the solvent, cleaning and oil have been set, the station will start performing the work cycle from STEP 1,
“Feeding solvent”, and the display will show the amount as it is injected into the automatic transmission circuit.