Beta Max SCAFF-TRAC 6-11 Скачать руководство пользователя страница 12

 12

         

BETA MAX PORTABLE HOIST SYSTEMS

TRESTLE MONORAIL

The universal mounting option system for all Beta Max portable hoists, the Trestle Monorail is ideal
for mounting on a flat roof or an intermediate floor. The system allows a 3.5 ft. cantilever. Two
people can assemble the system in minutes.

TRESTLE MONORAIL ANCHORING METHODS

Trestle Ceiling Brace: For use when the trestle will be installed on an intermediate floor of a build-
ing with a rigid structural ceiling above the trestle. The brace that locks the rear of the trestle
between the ceiling and the floor on which the system is mounted stabilize the trestle monorail.
After the trestle is assembled and placed in the desired location the jack is bolted to the top of the
inboard end of the monorail. The jack must be in firm contact with the ceiling structure.

Floor Tie Down Clamps: Most suitable for permanent applications. The clamps attach to the inboard
legs of the trestle and allow the system to be anchored by chains or wire rope.

Ballasting: A counterbalance system employing two rigid metal containers (each with a capacity of
9.5 cubic ft.) that are bolted to the inboard leg of the trestle. The weight of the material in the
ballast containers counterbalances the combined weight of the load and the hoist at the outboard
end of the trestle. Ballast material must conform to certain requirements. Bricks, solid concrete
blocks, stone or other high-density non-flowable materials are suggested.

Counterweighting: Uses counterweight clamps, which come complete with mounting hardware and
attach securely to the inboard legs of the trestle. This method lets you make use of flat steel coun-
terweights commonly used for roof outriggers. Standard 50 lb. counterweights slide down over the
27 in. upright.

Whatever anchoring method you use, additional tie back ropes should always be in place to secure
the system.

Содержание SCAFF-TRAC 6-11

Страница 1: ...HOIST MOUNTING SYSTEM 9 MAC TRAC ASSEMBLY AND MOUNTING 11 TRESTLE MONORAIL 12 TRESTLE MONORAIL ASSEMBLY 14 TRESTLE MONORAIL ANCHORING METHODS 15 MOUNTING THE HOIST ON A MONORAIL TRAC SYSTEM 16 VERTIC...

Страница 2: ...usage within the above described time Any defect in this equipment must immediately be brought to the attention of the distributor from whom the unit was purchased The distributor will make arrangemen...

Страница 3: ...stops the hoisting operation when the load has reached the upper limit of travel Different models of the hoist have different weight capacities cable lengths and minor differences in control configura...

Страница 4: ...iring to that job site and the length and type of extension power cable HOSE SIZE being used What about the FAUCET RESISTANCE If your faucet is rusted corroded or small or if the faucet is a long dist...

Страница 5: ...ge over 110 volt units because they allow for the use of longer extension cords less resistance 220 volts also require less AMPERAGE to run and therefore are able to run cooler and longer than 110 vol...

Страница 6: ...nd 2 mounting pins Extensions are butted up to the inboard end of the basic section and fitted into guide pins see diagram pg 7 Additional extension sections can be added as needed The mounting saddle...

Страница 7: ...tion is designed for use on any 6 ft walk thru scaffolding frames The X brace spacing between frames must be set at 7 ft A full width deck must be installed at the location of the hoist to provide ade...

Страница 8: ...mounting to various manufacturers scaffold frames These holes allow for minimum top to bottom ledger distance of 5 8 an intermediate distance of 6 and maximum distance of 6 1 4 INSTALLATION OF THE SCA...

Страница 9: ...1 5 8 tube frame scaffolding The system is set for 7 ft X bracing and the track cantilevers 2 ft out over the X brace side of your scaffolding tower By removing the X brace at the level work is perfor...

Страница 10: ...pt the roller wheels of the the Scorpio hoist model The Trac is slotted at the open end to make it easy to load the hoist Mounting stud bolts on the Trac fit into one of three 3 optional mounting loca...

Страница 11: ...l safety requirements to be sure Scaffolding frames must be in good condition and free of dents bends heavy corrosion cuts modifications or any other damage All X braces must be in place and secured b...

Страница 12: ...n Clamps Most suitable for permanent applications The clamps attach to the inboard legs of the trestle and allow the system to be anchored by chains or wire rope Ballasting A counterbalance system emp...

Страница 13: ...BETA MAX PORTABLE HOIST SYSTEMS 13...

Страница 14: ...ht A using bolts F Tighten loosely 2 Connect braces D in center towards each other using bolt E Tighten loosely This is tempo rary The uprights A should be approx 7 ft apart 3 attach Trac B to upright...

Страница 15: ...amps are adequate to attach to the trestle arch legs A heavy chain or equivalent should be used to connect the floor tie down clamps to the anchor bolts 3 Ballasting Two rigid metal containers each wi...

Страница 16: ...il Trac the inboard end of the Monorail Trac will have a lifting tendancy and must be properly counterbalanced or secured in place A load sus pended at the outboard end of the Monorail Trac will exert...

Страница 17: ...he system with the adjustment screw to lock the vertical post between the two surfaces Make sure the post is vertical to the floor Attach the tubular mounting clamps as high as possible on the window...

Страница 18: ...pening with side flanges on the OUTSIDE and toggles on the inside The larger diameter tube should be on top 3 Rotate the adjustment screw until the top and bottom plates are firmly against the window...

Страница 19: ...BETA MAX PORTABLE HOIST SYSTEMS 19...

Страница 20: ...ically apply the brake Always control the load motion with the control buttons DO NOT run the load into the ground and DO NOT use the UP Limit switch to stop upward motion The wire rope will stretch a...

Страница 21: ...ed CATALOG strength of a wire rope applies ONLY to a NEW UNUSED rope 4 The Nominal strength of a wire rope SHOULD BE CONSIDERED the straight line pull which will ACTUALLY BREAK a new UNUSED rope The n...

Страница 22: ...of PERMANENT RECORDS SIGNED BY A QUALIFIED PERSON are REQUIRED BY OSHA FOR ALMOST EVERY WIRE ROPE INSTALLA TION The purpose of inspection is to determine whether or not a wire rope or wire rope sling...

Страница 23: ...ful service life of a wire rope Contact with electrical wires and the resulting arcing will damage a wire rope WIRE ROPE SPECIFICATIONS Beta Max hoist come equipped with 19 x 7 rotation resistant wire...

Страница 24: ...rope diameter and length for your hoist model see rope size specification table pg 23 New wire rope must be terminated with a press fitting on the drum end of the rope see specifications for terminat...

Страница 25: ...evice other than press fitting such as a wire rope clip follow the manufactures specifications or the following method 1 Turn back the specified length of rope from the thimble Apply the first clip on...

Страница 26: ...e bent sharply pinched tied in a knot or otherwise damaged GEAR BOX The gear reduction assembly is maintenance free and permanently lubricated It should be in spected monthly for leaks or damage and s...

Страница 27: ...persons to stand under a loaded hoist DO NOT Exceed recommended duty cycle of the hoist DO NOT Exceed fuse rating recommended by the National Electric Code DO NOT Change the wiring leads of the limit...

Страница 28: ...erly wound on drums Hooks and clasps not deformed cracked or pulling apart Hook spring catch installed and not bent Wire rope is terminated properly ELECTRICAL SOURCE AND CABLES Voltage from source mu...

Страница 29: ...and work on 24 volt circuitry with remote control and 110 or 220 volts on standard units On remote control models a 24 volt output transformer is connected to the primary power when the unit is plugg...

Страница 30: ...justment ring 12 counter clockwise and then tightening 3 ea screw 14 pulling the bearing 9 and the inner air gap adjustment ring 8 back the tension is increased When adjusting the air gap the rotor 1...

Страница 31: ...turn 12 counter clockwise about 1 turn tighten 3 screw 14 equally in small incre ments while watching to see if the outer rod of bearing 9 begins to come in contact with the inner side of air gap adju...

Страница 32: ...32 BETA MAX PORTABLE HOIST SYSTEMS CONICAL BRAKE PARTS LIST...

Страница 33: ...BETA MAX PORTABLE HOIST SYSTEMS 33 TRANSMISSION DRUM ASSEMBLY...

Страница 34: ...34 BETA MAX PORTABLE HOIST SYSTEMS MOTOR BRAKE ASSEMBLY...

Страница 35: ...BETA MAX PORTABLE HOIST SYSTEMS 35...

Страница 36: ...36 BETA MAX PORTABLE HOIST SYSTEMS TECHNICAL SPECIFICATIONS...

Страница 37: ...BETA MAX PORTABLE HOIST SYSTEMS 37 TECHNICAL SPECIFICATIONS...

Страница 38: ...38 BETA MAX PORTABLE HOIST SYSTEMS TROUBLE SHOOTING...

Страница 39: ...BETA MAX PORTABLE HOIST SYSTEMS 39...

Отзывы: