background image

                       

BestScope International Limited

 

-

100× (Oil) (S) 

 

 

 

 

Seidentopf 
Binocular 
Head 

Inclined 30°, Rotatable 360°, 
Interpupilary Distance: 48-75mm 

 

 

 

 

Seidentopf 
Binocular 
Head (For 
Infinite 
System) 

Inclined 30°, Rotatable 360°, 
Interpupilary Distance: 48-75mm 

 

 

 

 

Trinocular 
Head 

Inclined 30°, Rotatable 360°, 
Interpupilary Distance 48-75mm, 
Light Distribution: 20:80 

 

 

 

 

Trinocular 
Head (For 
Infinite 
System) 

Inclined 30°, Rotatable 360°, 
Interpupilary Distance 48-75mm, 
Light Distribution: 20:80 

 

 

 

 

Nosepiece 

Quadplex 

 

 

 

 

Mechanical 
Stage 

Stage Size: 145X140mm 
Travel: 76mmX52mm 
Coaxial  Coarse  and  Fine  Focusing 
Knobs 

 

 

 

 

Condenser 

Abbe N.A. 1.25 
(Iris Diaphragm) 

 

 

 

 

Illumination 

3W  LED  Illumination  Systems, 
Brightness Adjustable 

 

 

 

 

6V/20W  Halogen  Lamp,  Brightness 
Adjustable 

 

 

 

 

Filter 

Blue 

 

 

 

 

Green 

 

 

 

 

Yellow 

 

 

 

 

NOTE

● Standard

○ Optional 

 

Packing Size: 420mm × 275mm × 450mm 
Gross Weight: 7.5 kgs                        Net Weight: 6.5 kgs 

 

 
 
 
 

 

Содержание BS-2036 Series

Страница 1: ...ical microscope To ensure the safety obtain optimum performance and to familiarize you fully with the use of this microscope it is recommended strongly that you study this manual thoroughly before usi...

Страница 2: ...enance 6 7 Troubleshooting 7 8 Outfits 8 BS 2036 series biological microscopes are designed for college teaching Medical and clinical identification The microscope with modern design steady structure...

Страница 3: ...cular Head Trinocular Head Power Input Fuse F L M N A Diopter Adjustment Ring B Nosepiece C Clamp Handle D Handle of Iris Aperture Diaphragm E Field Diaphragm Ring F Body Handle G Head Fixing Screw H...

Страница 4: ...e Field Resolving Power Working Distance 4X 0 10 5mm 2 8 m 16mm 10X 0 25 2mm 1 1 m 2mm 20X S Optional 0 40 1mm 0 69 m 1 1mm 40X S 0 65 0 5mm 0 42 m 0 66mm 100X Oil S 1 25 0 2mm 0 22 m 0 42mm BS 2036C...

Страница 5: ...spherical System 2 3 9 Filter Built in blue filer 2 3 10 Electric components Input voltage AC85 265V LED AC170 270V 50 60Hz Output voltage DC1 2 6V LED DC0 4 3 5V 6V 20W halogen lamp Rotation potenti...

Страница 6: ...phragm Adjust condenser condenser focusing screw M and aperture Aperture diaphragm lever D Observing 1 Turn power switch adjust light Turn on Switch L and turn Potentiometer K 2 Put the sample Put the...

Страница 7: ...preparation is suggested to clean it 6 1 4 Plastic should be cleaned by soft cloth with clear water 6 2 Environment of using and placing 6 2 1 Microscope should be used and placed in a cool dry non du...

Страница 8: ...t again Bulb is broken Replacing bulb Brightness of view field isn t enough or is Uneven Bulb specification doesn t meet the requirement Replacing bulb Brightness isn t adjusted correctly Adjust rotat...

Страница 9: ...en correctly Cover glass doesn t meet the requirement Use required thickness cover glass 0 17mm Image observed by two eyes aren t in superposition entirely Interpupilary distance isn t adjusted correc...

Страница 10: ...tribution 20 80 Trinocular Head For Infinite System Inclined 30 Rotatable 360 Interpupilary Distance 48 75mm Light Distribution 20 80 Nosepiece Quadplex Mechanical Stage Stage Size 145X140mm Travel 76...