2.1 Total magnifications 

                                          Objective 
          Total Magnifications 
Eyepiece 

4X 

10X 

20X 

(Optional) 

40X 

100X 

10X 

40X 

100X 

200X 

400X 

1000X 

16X 

64X 

160X 

320X 

640X 

1600X 

 
2.2

 

Objectives   

BS-2036A, BS-2036AT 

Achromatic Objective 

Numerical 

Aperture (N.A.) 

Objective 

Field 

Resolving 

Power 

Working 

Distance 

4X 

0.10 

4.5mm 

2.8µm 

13mm 

10X 

0.25 

1.8mm 

1.1µm 

6.3mm 

20X (S)    (Optional) 

0.40 

0.9mm 

0.69µm 

0.82mm 

40X (S) 

0.65 

0.45mm 

0.42µm 

0.44mm 

100X (Oil) (S) 

1.25 

0.18mm 

0.22µm 

0.3mm 

BS-2036B, BS-2036BT 

Plan Objective 

Numerical 

Aperture (N.A.) 

Objective 

Field 

Resolving 

Power 

Working 

Distance 

4X 

0.10 

5mm 

2.8µm 

16mm 

10X 

0.25 

2mm 

1.1µm 

2mm 

20X (S) (Optional) 

0.40 

1mm 

0.69µm 

1.1mm 

40X (S) 

0.65 

0.5mm 

0.42µm 

0.66mm 

100X (Oil) (S) 

1.25 

0.2mm 

0.22µm 

0.42mm 

 
BS-2036C, BS-2036CT 

Infinite E-Plan 

Objectives 

Numerical 

Aperture (N.A.) 

Objective 

Field 

Resolving 

Power 

Working 

Distance 

4X 

0.10 

5mm 

2.8µm 

6.73mm 

10X 

0.25 

2mm 

1.1µm 

4.19mm 

20X (S) (Optional) 

0.40 

1mm 

0.69µm 

2.14mm 

40X (S) 

0.65 

0.5mm 

0.42µm 

0.45mm 

100X (Oil) (S) 

1.25 

0.2mm 

0.22µm 

0.12mm 

 
BS-2036D, BS-2036DT 

Infinite Plan 

Objectives 

Numerical 

Aperture (N.A.) 

Objective 

Field 

Resolving 

Power 

Working 

Distance 

4X 

0.10 

5mm 

2.8µm 

12.1mm 

10X 

0.25 

2mm 

1.1µm 

4.64mm 

20X (S) (Optional) 

0.40 

1mm 

0.69µm 

2.41mm 

40X (S) 

0.65 

0.5mm 

0.42µm 

0.65mm 

100X (Oil) (S) 

1.25 

0.2mm 

0.22µm 

0.12mm 

Содержание BS-2036 Series

Страница 1: ...ical microscope To ensure the safety obtain optimum performance and to familiarize you fully with the use of this microscope it is recommended strongly that you study this manual thoroughly before usi...

Страница 2: ...enance 6 7 Troubleshooting 7 8 Outfits 8 BS 2036 series biological microscopes are designed for college teaching Medical and clinical identification The microscope with modern design steady structure...

Страница 3: ...cular Head Trinocular Head Power Input Fuse F L M N A Diopter Adjustment Ring B Nosepiece C Clamp Handle D Handle of Iris Aperture Diaphragm E Field Diaphragm Ring F Body Handle G Head Fixing Screw H...

Страница 4: ...e Field Resolving Power Working Distance 4X 0 10 5mm 2 8 m 16mm 10X 0 25 2mm 1 1 m 2mm 20X S Optional 0 40 1mm 0 69 m 1 1mm 40X S 0 65 0 5mm 0 42 m 0 66mm 100X Oil S 1 25 0 2mm 0 22 m 0 42mm BS 2036C...

Страница 5: ...spherical System 2 3 9 Filter Built in blue filer 2 3 10 Electric components Input voltage AC85 265V LED AC170 270V 50 60Hz Output voltage DC1 2 6V LED DC0 4 3 5V 6V 20W halogen lamp Rotation potenti...

Страница 6: ...phragm Adjust condenser condenser focusing screw M and aperture Aperture diaphragm lever D Observing 1 Turn power switch adjust light Turn on Switch L and turn Potentiometer K 2 Put the sample Put the...

Страница 7: ...preparation is suggested to clean it 6 1 4 Plastic should be cleaned by soft cloth with clear water 6 2 Environment of using and placing 6 2 1 Microscope should be used and placed in a cool dry non du...

Страница 8: ...t again Bulb is broken Replacing bulb Brightness of view field isn t enough or is Uneven Bulb specification doesn t meet the requirement Replacing bulb Brightness isn t adjusted correctly Adjust rotat...

Страница 9: ...en correctly Cover glass doesn t meet the requirement Use required thickness cover glass 0 17mm Image observed by two eyes aren t in superposition entirely Interpupilary distance isn t adjusted correc...

Страница 10: ...tribution 20 80 Trinocular Head For Infinite System Inclined 30 Rotatable 360 Interpupilary Distance 48 75mm Light Distribution 20 80 Nosepiece Quadplex Mechanical Stage Stage Size 145X140mm Travel 76...

Отзывы: