29
Electromagnetic Compatibility (EMC)
This machine has been designed in accordance with all relative directives and norms.
However, it may still generate electromagnetic disturbances that can affect other
systems like telecommunications (telephone, radio, and television) or other safety
systems. These disturbances can cause safety problems in the affected systems.
Read and understand this section to eliminate or reduce the amount of
electromagnetic disturbance generated by this machine.
This machine has been designed to operate in an industrial area. To
operate in a domestic area it is necessary to observe particular precautions
to eliminate possible electromagnetic disturbances. The operator must
install and operate this equipment as described in this manual. If any
electromagnetic disturbances are detected the operator must put in place corrective
actions to eliminate these disturbances with, if necessary, assistance from Lincoln
Electric. Before installing the machine, the operator must check the work area for any
devices that may malfunction because of electromagnetic disturbances. Consider the
following.
Input and output cables, control cables, and telephone cables that are in or adjacent
to the work area and the machine.
Radio and/or television transmitters and receivers. Computers or computer
controlled equipment.
Safety and control equipment for industrial processes. Equipment for calibration and
measurement.
Personal medical devices like pacemakers and hearing aids.
Check the electromagnetic immunity for equipment operating in or near the work area.
The operator must be sure that all equipment in the area is compatible. This may
require additional protection measures.
The dimensions of the work area to consider will depend on the construction of the
area and other activities that are taking place.
Consider the following guidelines to reduce electromagnetic emissions from the
machine.
Connect the machine to the input supply according to this manual. If disturbances
occur if may be necessary to take additional precautions such as filtering the input
supply.
The output cables should be kept as short as possible and should be positioned
together. If possible connect the work piece to ground in order to reduce the
electromagnetic emissions. The operator must check that connecting the work piece
to ground does not cause problems or unsafe operating conditions for personnel and
equipment.
Shielding of cables in the work area can reduce electromagnetic emissions. This may
be necessary for special applications.