25
Welding with Positive Polarity (DC+)
A delivered the machine is wired for Positive Polarity, which is required for solid wire.
The gun cable
is connected to the Positive (+) output terminal, but the work cable
is connected to the Negative (-) output terminal.
Welding with Negative Polarity (DC-)
The welding cables should be changed places on the output terminals: the gun cable
should be connected to the Negative (-) output terminal and the work cable
to the Positive (+) output terminal. This is the typical configuration is designed for Flux
Cored Welding (FCAW).
Final Action
Connect the work cable to the work piece with the work clamp.
Connect the shielding gas to the shielding gas input through the gas regulator.
Insert the plug of the input power cord of the welder into the outlet of the supply
network.
Switch on the welder. Switching on is indicated by lightening up of the power
indicator.
Based on seam kind, joint type and welded material thickness, select proper welding
settings with the welding voltage switch and the WFS control knob.
Obeying the appropriate regulations, you can start to weld.