background image

28

WARRANTY POLICY

Bestcare offers a limited warranty on all patient lifts, slings and accessories to be free of defects in workmanship and product 

performance. This warranty extends only to the original purchaser and is non-transferable. All warranty claims must be submitted by 

the authorized dealer or distributor who originally sold the product with proper proof of sale and serial number where applicable. Prior 

Return Authorization (RA) from Bestcare is required for all warranty replacements. Bestcare reserves the right to repair or replace only 

defective parts or accessories in lieu of a complete new patient lift. The repaired or replacement part shall be warranted for a period 

equal to the remainder of the warranty period of the defective part.

Bestcare does not provide advance replacements for warranty claims.  For situations where an end user requires a replacement in 

advance and before a warranty item can be returned, dealer or distributor must purchase the replacement at full cost.  All freight charges 

for the replacement are the sole responsibility of the dealer or distributor. When end user returns warranty item and item proves to be 

defective, Bestcare will issue full credit for the replacement less freight charges.

Product returned without RA number clearly marked on the package or product returned later than 30 days after authorization will be 

refused and returned at sender’s expense. Final disposition of warranty claims will be determined at the sole discretion of Bestcare.  

Warranty claims will be denied for any of the following: product abuse or misuse, accidental or malicious damage, improper installation, 

product used with parts, components or accessories with quality or specifications incompatible with product, adulterated product, user 

neglect, failure to maintain and service product as specified in the owner’s manual or care tag, serial number removed or defaced, or 

normal wear and tear. 

Bestcare warrants the following products and components beginning from the purchase invoice date for the specified time period:

WARRANTY PERIOD

PRODUCT OR COMPONENT

Three (3) Years

Patient lift frame or spreader bar

Two (2) Years

Actuator, control box, pendant, charger, weigh scale, Stand Aids ( all components of STA400 & STA450), or 

casters excluding normal tread wear

One (1) Year

Battery or hydraulic pump

Six (6) Months

Reusable fabric slings

Bestcare Single Patient Specific slings are designed for limited use with one patient and may not be laundered. Bestcare will replace 

any disposable sling found to have a manufacturing defect. Normal wear and tear will not be covered under warranty.

This warranty expressly excludes wearable components including but not limited to foam parts and caster tread.  Furthermore, this 

warranty is void and null for product that has not been purchased or paid for in full.

RETURN GOODS POLICY

Patient lifts may not be returned unless the wrong lift is shipped in error by Bestcare or the lift is heavily damaged or defective out of the 

box.  For all other items, purchaser may request a RA for purchased goods within thirty (30) days of purchase invoice date.  All returns 

must be received by Bestcare no later than thirty (30) days after authorization or the RA will be voided. Return package must be clearly 

marked with the RA number or the package may be refused and returned at sender’s expense. Returns are subject to a minimum 

restocking fee of 15% or more depending on the condition of the returned item. Patient lifts are subject to a minimum restocking fee 

of 25% or more.  Please note that patient lifts being returned must be in the original carton with all parts, components and packing 

materials included. Failure to comply with this requirement will incur higher restocking fees or a rejection of the return. Slings, parts and 

accessories may only be returned if they have not been used. There are no exceptions to this provision.

All freight charges are the sole responsibility of purchaser when any of the following occurs:  (i) ordering error where an incorrect item is 

shipped in accordance with purchase order, (ii) an order is canceled while in transit or (iii) delivery is refused by customer. 

Bestcare reserves the right to issue credit amounts based on strict adherence to this policy.

Содержание BestStand SA600

Страница 1: ...A N D L I F T M o d e l S A 6 0 0 Ensure the product has been assembled according to the instructions in this manual All operators should read and understand the instructions for safe and proper opera...

Страница 2: ...he manufacture date can be found on the serial number label that is located at the top of the mast The YY in the serial number is the manufacture year and the MM is the manufacture month This product...

Страница 3: ...ferred The SA600 has a compact base for maneuvering easily while still providing a wide lifting range The SA600 is compatible with the stand assist sling and sani sling with the option to add the knee...

Страница 4: ...out its intended Do Not Iron Item may not be smooted or finished with an iron Class II symbol To identify equipment is designed that a connection to electrical earth ground is not required Tumble Dry...

Страница 5: ...ise severely handicapped The patient lift should be used solely for transferring a user patient from one utility beds chairs toilets etc to another The patient lift should not be used for transporting...

Страница 6: ...nt DOES NOT consist of any materials or ingredients to which patients are exposed that may cause bodily harm or injury Prolonged exposure or physical contact with any part of the equipment WILL NOT ca...

Страница 7: ...HE SOLE PROPERTY OF BESTCARE LLC ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BESTCARE LLC IS PROHIBITED 9 8 2017 1 of 1 DaTong Wrench ALL DIMENSIONS IN MM 1 6 6 30 30 120...

Страница 8: ...7 66 4 B 733 9 28 9 C 951 8 37 5 D 40 0 1 6 E 460 5 18 1 F 908 5 35 8 G 788 4 31 0 H 567 8 22 4 I 277 9 10 9 J 696 3 27 4 K 289 9 11 4 L 288 2 11 3 M 127 3 5 0 N 36 0 1 4 SA600 B C A 600 D E M N K L...

Страница 9: ...ing Load 600 lb Unloaded Lift Weight 125 lb A Base Ext Width Closed 26 9 B Mast Height 41 7 C Base Length 41 5 D Front Caster Height 4 7 E Knee Pad Depth Range 2 8 F Knee Pad Height Range 20 2 23 7 G...

Страница 10: ...nuts and washers on the base bracket Step 3 Insert the mast and align the upper hole on the mast with the upper hole on the bracket Secure the mast to the bracket using the side bolt and nuts as follo...

Страница 11: ...lts using the EZ Tools as follows Step 5 Remove the plastic caps then all the bolt nut and washers on the boom Tighten the bolt and nut using the EZ Tools as follows Step 6 Secure the boom to the mast...

Страница 12: ...ep 8 Secure the upper end of the actuator to the boom bracket using a pin and retaining ring as shown Step 9 Attach the footplate to the base using the two hooks by lowering it onto the top surface of...

Страница 13: ...cure the parts with the bolt nut and washers using EZ Tools Step 11 Insert the kneepad frame into the tube located on the mast Pull the handle below the tube to fully insert the frame and release the...

Страница 14: ...13 Step 6 Power Control Unit UNLESS OTHERWISE SPECIFIED DATE DRAWN BY 2920 PACIFIC DRIVE NORCROSS GA 30071 ALL DIMENSIONS IN MM 1 6 0 1 M4 1 M5 4 3 2 5 M5 SCREWS M4 SCREWS...

Страница 15: ...r devices PREPARATION BEFORE LIFTING Twist the RED EMERGENCY STOP BUTTON clockwise Verify the Lifting and Lowering Functions by pressing either the UP or DOWN button on the hand control once Position...

Страница 16: ...onal Battery Pack Optional Power Control Unit Overview 15 1 Connect Actuator as shown above 2 Connect Hand Control as shown above WARNING Contains a long charger cord that may cause strangulation if u...

Страница 17: ...Pressed in Release When the emergency stop button is released the LCD Display Panel will show one of the four signs below The sign will display for 5 seconds Then the lift will go into standby mode an...

Страница 18: ...17 LED Indicator Green In Use Blank Standby Lifting Lowering Operating Lift Using Hand Control Operating Lift Using LCD Display Panel...

Страница 19: ...w the LCD Display Panel will show the sign on the left either when the emergency stop button is released or when a button on the LCD Display Panel is pressed Lift operation is deactivated Battery need...

Страница 20: ...odel Sling Size SL TP331 S SL TP332 M SL TP333 L SL TP334 XL Stand Assist Buttock Strap Stand Assist Sling Stand Assist Toileting Sling Available slings compatible with Stand Assist Lift 19 If the pat...

Страница 21: ...stabilize the sling during lifting 6 Have patient grasp the arms of the boom and tilt head back slightly 7 Make sure the patients feet are firmly on the platform and knees are touching the kneepads wi...

Страница 22: ...being lifted 6 Fit the Stand Assist sling following Fitting Stand Assist Sling instructions the Buttock strap MUST be used with the Stand Assist sling These slings are designed to compliment one anoth...

Страница 23: ...Have the patient s hands holding the handles For patients who cannot hold the handles have them hold their arms around the chest 6 Press the UP button on the hand control 7 Before the patient s body h...

Страница 24: ...oluntary movements or patients with limited postural control 1 Slide the sling down patient s back to lumbar position 2 Draw shoulder straps under the arms and around the chest into the front 3 Draw V...

Страница 25: ...10 years or 20 000 cycles The expected lifetime of the electrical components are 3 years Contact Bestcare for recycling information First Received Monthly Every 3 Months Check connections between boo...

Страница 26: ...ngs with rigid supports remove the plastic inserts before washing Look for an opening near the plastic inserts for removal Machine wash warm or cold Do not wash with other colors Air dry or very low d...

Страница 27: ...on usage The actuator will either go up or down but not both Replace your hand control as it is at the end of its life cycle Your control box may be malfunctioning There is a grinding sound inside th...

Страница 28: ...cy Lowering Device is located at the top of the actuator shaft It is intended for use if the actuator or electronics fail to operate while the patient is suspended in midair The device consists of a p...

Страница 29: ...e date for the specified time period WARRANTY PERIOD PRODUCT OR COMPONENT Three 3 Years Patient lift frame or spreader bar Two 2 Years Actuator control box pendant charger weigh scale Stand Aids all c...

Страница 30: ...Notes 29...

Страница 31: ...Notes 30...

Страница 32: ...Bestcare LLC 2920 Pacific Drive Norcross GA 30071 Ver 2020 02 www bestcarellc com 2019 Bestcare LLC...

Отзывы: