background image

LIFTING HINTS

•  Prior to beginning a lift, have the patient lean slightly back and look at a 45 degree 

angle to the ceiling; this help position the sling; this is recommended only at the start 

of lifting.

• 

Try the sling straps in various color positions to establish best fit.

•  Always insure the same color straps on each side are attached to lift.

•  Should patients have a larger girth in mid section or back side area try the optional 

buttock strap to help with initial lift leverage.

•  Remember this lift is designed for pivot transfers and it is not necessary to lift to full 

upright position; as long as the patients body clears the bed or the chair and vice 

versa, you can move the lift and place patient in new position.

1. Fit sling as described in “Fitting Stand Assist Sling”.

2. Push lift towards patient. Open the base of the lift.

3. Position patient’s feet on the footplate and knees against the knee pad.

4. Attached the sling straps to the hooks.

5. Have the patient’s hands holding the handles. For patients who cannot hold the 

handles, have them hold their arms around the chest.

6. Press the “UP” button on the hand control.

7. Before the patient’s body has lifted from the bed, stop and make sure the sling 

is secured and patient’s knees are against the knee pad.

8. The patient should be comfortable with the pressure under the arms. If not, ad-

just the sling and try another loop option to release pressure.

9. Press the “UP” button until the patient’s body has completely left the bed.

10. Transfer to another object can be done at this position without the patient  

attending a full standing position.

11. Close the base, and pull the lift away from the bed.

12. Lower the patient to the object intended.

13. To lift patient in a standing position, continue to lift until the patient’s knees are 

locked in a standing position.

14. At the standing position, patient’s knees may move away from the knee pad.

15. Close the base, and pull the lift away from bed.

16. Lower the patient to the object intended.

17. Reverse the above procedures when lowering the patient to the object intended.

22

LIFT AND TRANSFER FROM BED

Содержание BestStand SA600

Страница 1: ...A N D L I F T M o d e l S A 6 0 0 Ensure the product has been assembled according to the instructions in this manual All operators should read and understand the instructions for safe and proper opera...

Страница 2: ...he manufacture date can be found on the serial number label that is located at the top of the mast The YY in the serial number is the manufacture year and the MM is the manufacture month This product...

Страница 3: ...ferred The SA600 has a compact base for maneuvering easily while still providing a wide lifting range The SA600 is compatible with the stand assist sling and sani sling with the option to add the knee...

Страница 4: ...out its intended Do Not Iron Item may not be smooted or finished with an iron Class II symbol To identify equipment is designed that a connection to electrical earth ground is not required Tumble Dry...

Страница 5: ...ise severely handicapped The patient lift should be used solely for transferring a user patient from one utility beds chairs toilets etc to another The patient lift should not be used for transporting...

Страница 6: ...nt DOES NOT consist of any materials or ingredients to which patients are exposed that may cause bodily harm or injury Prolonged exposure or physical contact with any part of the equipment WILL NOT ca...

Страница 7: ...HE SOLE PROPERTY OF BESTCARE LLC ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BESTCARE LLC IS PROHIBITED 9 8 2017 1 of 1 DaTong Wrench ALL DIMENSIONS IN MM 1 6 6 30 30 120...

Страница 8: ...7 66 4 B 733 9 28 9 C 951 8 37 5 D 40 0 1 6 E 460 5 18 1 F 908 5 35 8 G 788 4 31 0 H 567 8 22 4 I 277 9 10 9 J 696 3 27 4 K 289 9 11 4 L 288 2 11 3 M 127 3 5 0 N 36 0 1 4 SA600 B C A 600 D E M N K L...

Страница 9: ...ing Load 600 lb Unloaded Lift Weight 125 lb A Base Ext Width Closed 26 9 B Mast Height 41 7 C Base Length 41 5 D Front Caster Height 4 7 E Knee Pad Depth Range 2 8 F Knee Pad Height Range 20 2 23 7 G...

Страница 10: ...nuts and washers on the base bracket Step 3 Insert the mast and align the upper hole on the mast with the upper hole on the bracket Secure the mast to the bracket using the side bolt and nuts as follo...

Страница 11: ...lts using the EZ Tools as follows Step 5 Remove the plastic caps then all the bolt nut and washers on the boom Tighten the bolt and nut using the EZ Tools as follows Step 6 Secure the boom to the mast...

Страница 12: ...ep 8 Secure the upper end of the actuator to the boom bracket using a pin and retaining ring as shown Step 9 Attach the footplate to the base using the two hooks by lowering it onto the top surface of...

Страница 13: ...cure the parts with the bolt nut and washers using EZ Tools Step 11 Insert the kneepad frame into the tube located on the mast Pull the handle below the tube to fully insert the frame and release the...

Страница 14: ...13 Step 6 Power Control Unit UNLESS OTHERWISE SPECIFIED DATE DRAWN BY 2920 PACIFIC DRIVE NORCROSS GA 30071 ALL DIMENSIONS IN MM 1 6 0 1 M4 1 M5 4 3 2 5 M5 SCREWS M4 SCREWS...

Страница 15: ...r devices PREPARATION BEFORE LIFTING Twist the RED EMERGENCY STOP BUTTON clockwise Verify the Lifting and Lowering Functions by pressing either the UP or DOWN button on the hand control once Position...

Страница 16: ...onal Battery Pack Optional Power Control Unit Overview 15 1 Connect Actuator as shown above 2 Connect Hand Control as shown above WARNING Contains a long charger cord that may cause strangulation if u...

Страница 17: ...Pressed in Release When the emergency stop button is released the LCD Display Panel will show one of the four signs below The sign will display for 5 seconds Then the lift will go into standby mode an...

Страница 18: ...17 LED Indicator Green In Use Blank Standby Lifting Lowering Operating Lift Using Hand Control Operating Lift Using LCD Display Panel...

Страница 19: ...w the LCD Display Panel will show the sign on the left either when the emergency stop button is released or when a button on the LCD Display Panel is pressed Lift operation is deactivated Battery need...

Страница 20: ...odel Sling Size SL TP331 S SL TP332 M SL TP333 L SL TP334 XL Stand Assist Buttock Strap Stand Assist Sling Stand Assist Toileting Sling Available slings compatible with Stand Assist Lift 19 If the pat...

Страница 21: ...stabilize the sling during lifting 6 Have patient grasp the arms of the boom and tilt head back slightly 7 Make sure the patients feet are firmly on the platform and knees are touching the kneepads wi...

Страница 22: ...being lifted 6 Fit the Stand Assist sling following Fitting Stand Assist Sling instructions the Buttock strap MUST be used with the Stand Assist sling These slings are designed to compliment one anoth...

Страница 23: ...Have the patient s hands holding the handles For patients who cannot hold the handles have them hold their arms around the chest 6 Press the UP button on the hand control 7 Before the patient s body h...

Страница 24: ...oluntary movements or patients with limited postural control 1 Slide the sling down patient s back to lumbar position 2 Draw shoulder straps under the arms and around the chest into the front 3 Draw V...

Страница 25: ...10 years or 20 000 cycles The expected lifetime of the electrical components are 3 years Contact Bestcare for recycling information First Received Monthly Every 3 Months Check connections between boo...

Страница 26: ...ngs with rigid supports remove the plastic inserts before washing Look for an opening near the plastic inserts for removal Machine wash warm or cold Do not wash with other colors Air dry or very low d...

Страница 27: ...on usage The actuator will either go up or down but not both Replace your hand control as it is at the end of its life cycle Your control box may be malfunctioning There is a grinding sound inside th...

Страница 28: ...cy Lowering Device is located at the top of the actuator shaft It is intended for use if the actuator or electronics fail to operate while the patient is suspended in midair The device consists of a p...

Страница 29: ...e date for the specified time period WARRANTY PERIOD PRODUCT OR COMPONENT Three 3 Years Patient lift frame or spreader bar Two 2 Years Actuator control box pendant charger weigh scale Stand Aids all c...

Страница 30: ...Notes 29...

Страница 31: ...Notes 30...

Страница 32: ...Bestcare LLC 2920 Pacific Drive Norcross GA 30071 Ver 2020 02 www bestcarellc com 2019 Bestcare LLC...

Отзывы: