Storage Temperature:  5° - 122° F (-15° to +50° C). Battery life is reduced above 77° F (25 ° C).

If the Fortress unit is stored, the batteries should be recharged every 6 months.
If stored above 77° F (25° C), recharge the batteries more often.

Humidity: 5% - 95% RH (non-condensing).

Dimensions (Height x Width x Depth): 750 VA:

3.5 in. x 17.6 x 18.7 (88 x 448 x 475 mm)

1050 & 1425VA:

5.3 in. x 17.6 x 18.7 (133 x 448 x 475 mm)

1800 & 2250 VA:

7.0 in. x 17.6 x 18.7 (178 x 448 x 475 mm)

Weight: 750:

39.6 lbs. (18.0 kg)

1425:

57.2 lbs. (26.0 kg)

1050:

51.3 lbs  (23.3 kg)

1800 & 2250: 86.0 lbs. (39.1 kg)

Warranty

LIMITED TWO YEAR WARRANTY
Standard Warranty For All Purchases

BEST POWER, a division of General Signal Power Systems, Inc. (hereinafter called BEST POWER) 
warrants that each product sold by BEST POWER is compatible with existing commercially available 
computer equipment with enclosed power supplies and is free from defects in materials and workmanship
under normal use and service. This warranty is applicable only to the initial retail purchaser (PURCHAS-
ER), and is not transferable. The duration of this warranty is two (2) years from the date of the first retail
sale or the date of delivery to the PURCHASER, whichever occurs first, subject to the following conditions.

If the PURCHASER discovers within the duration of this warranty a failure of the product to perform 
compatibly with presently existing computer equipment or a defect in material or workmanship, the 
PURCHASER must promptly notify BEST POWER in writing within the duration of the warranty or not
later than one month after expiration of the warranty. BEST POWER’s obligation under this warranty is
limited to the replacement or repair, subject to the conditions specified below, of such product returned
intact to BEST POWER which shall appear to BEST POWER, upon inspection, to have been either 
incompatible or defective. Replacement or repair will be made at BEST POWER’s Worldwide Service,
Highway 80, Necedah, Wisconsin 54646, U.S.A. Such repair or replacement shall be at BEST POWER’s
expense. This warranty does not cover any taxes which may be due in connection with replacement or
repair, nor any installation, removal, transportation or postage costs. These expenses will be paid by 
PURCHASER. If BEST POWER is unable to repair or replace the product to conform to this warranty after
a reasonable number of attempts, BEST POWER will refund the purchase price. Remedies under this 
warranty are expressly limited to those specified above.

TO THE EXTENT ALLOWED BY LAW, BEST POWER DISCLAIMS ALL OTHER WARRANTIES,
EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, AND ANY IMPLIED 
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS
PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. TO THE
EXTENT ALLOWED BY LAW, BEST POWER SHALL NOT BE LIABLE FOR ANY SPECIAL, 
INCIDENTAL, OR CONSEQUENTIAL DAMAGES INCLUDING, BUT NOT LIMITED TO, LOSS OF
PROFITS, INJURIES TO PROPERTY, LOSS OF USE OF THE PRODUCT OR ANY ASSOCIATED
EQUIPMENT.

Содержание Fortress 1050 VA

Страница 1: ...USER GUIDE Fortress Rackmount 750 VA 1050 VA 1425 VA 1800 VA and 2250 VA...

Страница 2: ...ge must be limited to 3 mA on the U model and 2 5 mA on the E model If you do not know the load leakage current replace the UPS power cord with a power cord that uses a lock ing plug with a minimum ra...

Страница 3: ...F o r t r e s s Rackmount 750 VA 1050 VA 1425 VA 1800 VA and 2250 VA User Guide FSS 0388B Copyright 1998 Best Power All rights reserved...

Страница 4: ...he unit If you prefer you can contact Best on the World Wide Web to get more product information Best s toll free Fax on Demand service is also available 24 hours a day to give you access to technical...

Страница 5: ...eplacing the Batteries 10 Battery Replacement Instructions 11 Communication Port 12 DB 9 Pinouts 13 Specifications 13 Warranty 15 Appendix A Adjusting Voltage Settings 17 Best Power Offices 20 Tradema...

Страница 6: ...bove 25 Celsius 77 Fahrenheit recharge the batteries more often CAUTION Whenever the Fortress is On there may be dangerous voltage present at the unit s outlets This is true because the unit s battery...

Страница 7: ...panel LEDs and an audible alarm keep you aware of the unit s sta tus Use the drawings on this and the following page to identify features of the unit Line Buck boost Battery Mode Load or Battery Char...

Страница 8: ...ULT 1050 1425 E 1050 1425 U 1 Status Indicators 8 5 15 Outlets 1800 and 2250 2 On Standby Button have breaker 3 Alarm Program Button 9 5 20 Outlets 2250 has breaker 4 Battery Access Panel 10 L5 30 Out...

Страница 9: ...hardware from electronics distributors below the intended rack location for the Fortress Secure the shelf or brackets at both the front and back of the rack using bolts nuts and washers Carefully lift...

Страница 10: ...main on If the unit beeps or if the top light does not remain on even though input power is available from the wall outlet go to the Troubleshooting section 4 Switch off the equipment you want to prot...

Страница 11: ...s labled Site Wiring Fault lights to indicate a wiring fault in the circuit to which the Fortress is connected If this LED is on the outlet needs to be checked and repaired by an electrician Do not us...

Страница 12: ...is running on battery power Output Overload Refer to Tables 2 and 3 Replace the Battery or UPS Fault Refer to Tables 2 and 3 Blinking The unit is boosting or bucking utility power Boost Automatically...

Страница 13: ...onds 1 Utility power outage 2 Loose plug 3 Tripped circuit breaker 4 Power cord failure 1 Wait for power to return 2 Make sure the power cord is connected 3 Reset the circuit breaker 4 Phone Best Powe...

Страница 14: ...s could fall into the UPS Never allow any tool to contact both a battery terminal and the UPS cabinet or another battery terminal Do not lay tools or metal parts on top of batteries To ensure continue...

Страница 15: ...plug the protected load equipment from the Fortress Then turn off the Fortress and disconnect the line cord 3 Use the drawings below to identify the location on the battey pack in the model Fortress t...

Страница 16: ...l to the front panel 11 If you followed the option in step 2 Reconnect the line cord to the Fortress and turn the unit on 12 Reconnect the load equipment Switch on the protected load equipment one pie...

Страница 17: ...n 9 Unused Contacts consist of open collector circuits capable of switching up to 30 VDC 6 mA resistive load Specifications Best Power reserves the right to change specifications without prior notice...

Страница 18: ...me to 95 of capacity 750 VA 1050 VA 1425 VA 1800 VA and 2250 VA 3 hours 1425 VA 7 hours with output fully loaded Recharge time is lower with reduced load Overcurrent Protection on line All Models Circ...

Страница 19: ...he PURCHASER must promptly notify BEST POWER in writing within the duration of the warranty or not later than one month after expiration of the warranty BEST POWER s obligation under this warranty is...

Страница 20: ...the Product beginning with the date of sale to the initial retail purchaser subject to the following conditions This warranty is applicable only to the initial retail purchaser hereinafter called PURC...

Страница 21: ...above limitation on duration of implied warranties may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusio...

Страница 22: ...en input voltage rises to 130 the Fortress begins to decrease buck the output voltage With 146 volts input or higher the Fortress switches to battery power 3 Use the appropriate table on the next page...

Страница 23: ...146 156 1 2 5 90 104 128 146 156 Table 4 Voltage Settings for U Models 750 1050 1425 1800 and 2250 VA Table 5 Voltage Settings for E Models 750 1050 1425 and 2250 VA 270 244 230 200 180 3 4 6 284 250...

Страница 24: ...NGAPORE 188647 Telephone 65 430 6168 FAX 65 430 6170 Sola Australia Ltd 13 Healey Road Dandenong Victoria 3175 AUSTRALIA Telephone 61 3 9706 5022 FAX 61 3 9794 9150 BEST House Wykeham Industrial Estat...

Страница 25: ...is equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules These limits are designed to provide reasonable protection against harmfu...

Страница 26: ...FSS 0388A...

Отзывы: