Test UPS on battery back-up, switch off utility supply and observe ‘backup indicator’ 
lights. Also your PC should continue to function normally.

1. Self-testing while Turn ON

    Before turning on the UPS, the red/yellow/green led will be bright twice by turns.
    then the UPS will be ready for operation.

2. Silence Function

    In Battery Mode, shortly press the switch will enable or disable the buzzer.
    But when UPS is low battery or overload, the buzzer can not be silenced.

3. Overload Protection

    When UPS is overloaded while operating, which is not solved by the user in time,
    it will cut off the output automatically after short time.

4. Autorun DC Start & AC Start

    In DC mode, UPS discharges till battery run out and cut off, UPS autorun when
    AC recover.

5. Low Battery shutdown

    When the battery is about to be exhausted, UPS will shut down automatically to
    protect battery’s life.

6. Turn Off UPS

    1. AC Normal   UPS will cut off the output and goes to AC standby mode by
                             pressing the switch.
    2. Backup         Press the switch, the UPS will be turned off after a long beep.

7. Manual Self-testing

    User need to check the UPS ready for operation, Press the botton two time quickly
    then UPS self test, UPS transfer AC to Backup and Backup to AC.

The trouble shooting chart covers most of the difficulties that you may encounter
under normal working conditions. If the UPS fails to operate properly, please review
the following steps before calling the service center.

1. Is the UPS plugged into a correct working outlet?
2. Is the line voltage within the rating specified?
3. Is the Fuse or Breaker / Circuit Protector on back panal open?
4. UPS has used long time > 2 Year that is short backup time or fault.

Please submit the following information when you call for service.

1. Model No. & Serial No.
2. Date of problem.
3. Full desciption of problem UPS.

OPERATION AND TEST THE UPS

TROUBLE SHOOTING

TROUBLE SHOOTING CHART

Red LED continuous
bright with a beep every
8 seconds

UPS can not be turned
ON

UPS is not connecting
to AC and overloaded

Please connect to AC
and reduce the load

Please check the AC
Input Voltage

Please send to the 
agency to repair

Replace the Fuse or Reset
the breaker, remove some
load and check if the load
is short-circuit or faulty

The input Fuse is burn
or Breaker is off

UPS suddenly turns to
Battery mode in spite of
utility line present

Save the data promptly
and Shut down the 
operating system

Backup time less than
1 minute (low battery)

Close load and recharge
immediately

Battery problem

Replace the new battery

Recharge the battery for
atleast 12 hours and
retest the backup time

Use UPS > 2 year

Replace the new battery

Charging unit fault

Please send to the
agency to repair

Use more load over

Battery is not fully
charged

AC Input voltage is too
low

The UPS is failure

Red LED continuous
bright with a beep every
1 seconds

Back-up time less than
specified

Front Panel

Rear Panel

 MO850i / MO900i / 
MO1000i / MO1100i      

 MO1250i / MO1600i      

1. Power      2. Backup      3. Normal     4. Overload

Specification 

Model

                        

MO850i  MO900i  MO1000i  MO1100i MO1250i MO1600i

Power Rate(VA/W)     

850/325  900/390  1000/480  1100/550  1250/750     1600/960

Input Voltage

 

         220 Vac -34%, +32% (145-290 Vac)

Output Voltage (AVR)

 

            220 Vac +10% (198-242 Vac)

Output Voltage (Backup)

 

          220 Vac +3% (213.4-226.6 Vac) 

Battery Capacity    

     SLA 12V 5.4Ah  x  1     SLA 12V 7.2Ah x 1   7.2Ah x 2   9.4Ah x 2

Backup Time

 

                 15-40min (Depened on Load)

Charging Time

 

          Batt. Cap.90% in 3-6 Hours

Protection System

            Over / Under Voltage, Over Load, Shot Circuit Protection

                            Low Battery Shutdown Fault and Battery Replacement

Transfer Time

 

 

           4-10msec

LED Display      

         Normal, Backup, Overload, Low Battery, Battery Replacement

Audible Alam

                     Backup mode, Low battery, Overload, Fault

AC Line Surge Protector

            1,000,000W in 100

µ

s

 / 160 Joules in 2 ms

Tel / ADSL Surge TVSS

  

             Tel / Fax / ADSL / RJ11 / RJ45

Standard Certification

   ISO9001/14001, TIS.1291 1-2553, 2-2553, 3-2555, CE : IEC62040

Environment

 

        0-45

°

C / RH 0-90% Non condensing

Dimensions (WxHxD)mm.

                 100x330x155                  146x345x162

Weight kg.              

4.3       4.6       5.0       5.2          8.5       10.2