Installation Instructions for Wi-Q™ Technology 9KQ Cylindrical Locks
11
Installation Instructions for Wi-Q™ Technology 9KQ Cylindrical Locks
Installing the lock
BEST ACCESS SYSTEMS
a Product Group of dormakaba USA Inc.
15
Connect motor wires, RQE, and
door status switch
1 From the inside of the door, make the following
connections:
◆
Motor
◆
RQE
◆
Door status switch
2 Insert the plastic wire tie through the mounting clip
and secure the wires as shown in Figure 15. See Figure
15 for additional detail.
Caution:
When making the motor connection,
make sure:
◆
there are no loose wire connections where the
wires are inserted into the connectors
◆
the connectors are firmly mated.
Wire connection
Color
No. of
wires
No. of
pins
Motor
Yellow-Gray
2
2
RQE
Orange-Brown
2
3
Door status
White
2
2
Figure 15 Routing the wires (view of the inside
escutcheon)
Route wire
harness on
the left side
of the fire
plate.
Mounting
clip and
wire tie
Dress wires so
that wire connec-
tors are mated
here. Use electric
tape to affix them
as needed.
Antenna wire
Battery
connector