Besam AAE977 Скачать руководство пользователя страница 5

Intial Sensor Setup

 

1

.Power up the Unislide and tune the door. 

(Unislide control V12.16.2 and above)

 

 

a

.Remove the control cover and flip dipswitch #7 to OFF (down); turn the time  

 

 

 

delay counterclockwise and disconnect the breakout switch terminal block and  

 

 

 

keep P1/P2 disconnected.

 

 

b

.Slide door(s) closed and with the 5-position switch in Auto mode, press the   

 

 

 

Learn button located on the bottom edge of the control.  The door should cycle  

 

 

 

slow open - slow closed.

 

 

c

.Put the 5-position switch to Hold-Open and observe the door cycle for back   

 

 

 

check functionality and make door adjustments if required and turn the time    

 

 

 

delay to a minimum of 1.5 seconds.

 

 

d

.Connect P1 and P2 (P2 = side not intended for use during a “1-way” traffic   

 

 

 

mode) to the adapter board.

 

 

e

.Open the Unislide cover and on the Unislide control box, flip dipswitch #7 ON  

 

 

 

(for monitoring).  Close the cover to the control box.

 

 

f

.Close and latch Unislide cover. Set the rotary switch to the “Auto”, two-way   

 

 

   

traffic position. Momentarily press the reset button located next to the 5-position  

 

 

 

switch.

  2

.The Ultraview sensors are factory set in “Neutral” mode.  To set up the system,

  the sensors will need to be designated as P1 or P2, and then the sensors will need to   

 

  be configured for the particular installation.  The system will not properly function until the    

  sensors are designated.  

  3

.On the sensor to be designated as P1, confirm that it is connected to P1 at the interface    

  board then press the left push button for 3 seconds and release.The LED will flash green once  

(meaning set to P1), and then steady red. The sensor will establish communication with the  

 

  other sensor and the LED on both sensors will flash slowly green (1 Hz) for 2 minutes 

 

duration, and the other sensor will automatically be designated P2.

 

4

.If the sensor is designated incorrectly, press and hold the left push button of the P1  

 

 

sensor for 5 seconds and the sensor will return to neutral mode.  The LED will flash green  

 

 

three times when the push button is released.  Then repeat step 2.

 

 

5

.Mechanically adjust the presence field of each sensor for the installation.

 

 

a

.Launch a setup of the system by momentarily pressing and releasing the right  

 

 

 

push-button (on either sensor), and then step away from the pattern. This will  

 

 

 

launch a setup for both sensors at the same time. Adjust one sensor at a time 

 

 

thereafter. Keep traffic away from the sensor’s pattern. 

 

 

If the right push-button is pressed for 3 seconds, the sensor will be in a  

 

 

 

manual set-up mode. The sensor will flash red, then green a number of  

 

 

 

times. To return to the standard mode press the right push button again for    

 

 

3 seconds until the LED light stops flashing and then release.

 

 

b

.The sensor will automatically go through a set-up and the LED will flash red/green    

 

 

a number of times.  The door will open, then close while the LED is flashing (the 

 

 

sensors are learning the influence of the door) - this will take approximately 

 

 

16 seconds

 

 

c

.The LED will display one of four conditions: 

 

 

 

 

d

.If needed, turn the adjustment screw with a small screwdriver ½ revolution, then    

 

 

repeat step 5a. 

 

 

e

.Repeat steps ‘a’ through ‘d’ for the other side of the door.

 

 

f.If any operator adjustments are made a new setup must be launched.

 

6

.Connect the break-out switch connector (see picture Step 1) and secure the header cover.

 

7.

(Once the Unislide and Ultraview covers are installed and secured in place). Launch a final    

 

set-up via the remote control (magic wand 0) 

 

 

Ultraview US23-0640-09 

 

 

 

 

 

07-30-09 

 

 

                 V4 

© Copyright 2009 Besam US Inc.  May not be reprinted without ermission               

 

                        5

LED STATUS

 

 

 

   

   MEANING

 

 

 

               

 ACTION

(after pushing right pushbutton)

Rapid flashing RED

Rapid flashing Green

None

ORANGE

Presence pattern is too close to door

Presence pattern is too far from door 

Presence pattern is properly positioned

ERROR

Adjust screw counterclo)

Adjust screw clockwise(-)

None

See Troubleshooting Guide on pg. 11

BREAKOUT

SWITCH

TIME

DELAY

DIP

SWITCH#7

LEARN

BUTTON

1.)PRESS LEFT

BUTTON

2.)OBSERVE LED

Note: Before connecting and tuning the sensors, complete all operator adjustments and verify 

proper operation of the door system for compliance with applicable ANSI standards

STEP 1

Содержание AAE977

Страница 1: ...0 09 07 30 09 V4 Copyright 2009 Besam US Inc May not be reprinted without permission 1 Complies with ANSI BHMA A156 10 Standard for Power Operated Pedestrian Doors UL325 Listed Besam UltraView Install...

Страница 2: ...r detection performance SPECIAL NOTE The Ultraivew works differently than the BEA Wizard When making changes to the Ultraview reference the Ultraview users guide If you inadvertently make changes base...

Страница 3: ...roduct conformity R TTE 1999 5 EC EMC 89 336 EEC FCC Interface Factory Installed Technology Microwave and microprocessor Transmitter frequency 24 125 GHz Transmitter radiated power 20 dBm EIRP Transmi...

Страница 4: ...connector on the Ultraview Interface Board Ultraview US23 0640 09 07 30 09 V4 Copyright 2009 Besam US Inc May not be reprinted without permission 4 MOUNTING SCREWS INFRARED LENS SHROUD SENSOR COVER U...

Страница 5: ...the push button is released Then repeat step 2 5 Mechanically adjust the presence field of each sensor for the installation a Launch a setup of the system by momentarily pressing and releasing the rig...

Страница 6: ...LENS FACTORY DEFAULT 6 6 W X13 75 D CHANGE PRESENCE LENS IF NEEDED REMOVE BEZEL OPTIONAL NARROW ANGLE ANTENNA ADJUST ANGLE BY TILTING MICROWAVE CELL 7 0 height 13 W X 6 6 D 6 6 W X 8 2 D Wide Narrow...

Страница 7: ...t off main power to the Unislide wait 5 seconds 6 Re apply power 7 Unlock P1 press unlock then 1 8 Press magic wand on the remote control 9 Press 0 this will launch a set up Keep traffic away from the...

Страница 8: ...rol 0 min 9 max default 7 Sensitivity Microwave Detection Mode 1 bidirectional mode 2 unidirectional mode 3 unidirectional mode with MTF Setup launch an assisted setup restore factory settings When re...

Страница 9: ...he door will not re cycle open at this time it will continue to close because the motion output is going to the Outer Impulse at the control box which has been ignored due to the 1 way traffic selecti...

Страница 10: ...eter being altered 1 flash means value 1 The right button enables selection of the parameter number being altered 1 for each press The left button enables alteration of the value 1 for each press EXAM...

Страница 11: ...resence If LED s are illuminat ing make sensor adjustments as necessary to eliminate unwanted detection Check angle and sensitivity for presence and motion see pg6 2 Check for moving objects in the pa...

Страница 12: ...pressing the reset button next to the 5 position switch 3 Select correct sensor with P1 1 Reset system to neutral 2 Power Off On by pressing the reset button next to the 5 position switch 3 Select co...

Страница 13: ...ows the User to toggle between STD and AUX The STD position is the default position The AUX position is selected for applications that require initial activation by the Knowing Act device only Thus wh...

Страница 14: ...cover position to the 1 way traffic mode The AUX input will not be acknowledged when placed in the STD position KNOWING ACT TO PUSH PLATES DRY CONTACT ONLY DIP SWITCH P1 P2 TO BREAKOUT SWITCHES 1 Wir...

Страница 15: ...activation regardless of door position 3 Setting the rotary switch to the OFF position will disable all inputs once the door is fully closed c Part Time 1 Way Security Day Night Mode Set STD AUX swit...

Страница 16: ...bottom guide assembly for proper adjustment and excessive wear 13 Check door closing speed and closing force 14 Check closing latch location 15 Check that door hold open time is 1 5 seconds or longer...

Отзывы: