![Besam AAE977 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/besam/aae977/aae977_installation-manual_2739549014.webp)
Ultraview US23-0640-09
07-30-09
V4
© Copyright 2009 Besam US Inc. May not be reprinted without permission
1 4
patterns as defined by the Re-Entry Zone, as programmed by the remote control (see page
10 for the correct key). When using the AUX position, each Ultraview sensor must have the
microwave Re-Entry Zone configured to meet the requirements of a secondary activation
sensor.
The AUX input (when toggled to the AUX position) will be recognized by the control at any
Unislide On-Off switch position other than the OFF position.
For applications requiring a standard 1-way traffic mode, simply leave the Ultraview switch
in the STD position, and then place the Unislide On/Off switch (on the Unislide header access
cover) position to the 1-way traffic mode. The AUX input will not be acknowledged when
placed in the STD position.
KNOWING ACT:
TO PUSH PLATES
(DRY CONTACT ONLY)
DIP SWITCH
P1
P2
TO BREAKOUT
SWITCHES
1) Wire push plate to AUX input
2) Dip switch to AUX position
3) 5 position key switch to one-way
4) Set re-entry key on both sensors (24”)
1) Wire push plate to AUX input
2) Dip switch to AUX position
3) 5 position key switch to two-way
4) Set re-entry key on P1
Note: if key switch is set to one-way,
set re-entry key on P2 also.
(night mode)
1) Wire push plate to AUX input
2) Plate side sensor needs to be plugged
into P1 connector on interface
3) Dip switch to AUX position
4) Set sensor to neutral
5) Designate P1 sensor
6) Set 5 position switch to two-way
7) Set re-entry key on P1
2 push plate application
1 plate (cover side)
1 plate (plank side)
Example applications
Troubleshooting-continued (P1 and P2 related errors)
JUMPER