3.4.3

 

Channel 1/2 Delays 

 

These parameters allow to configure time delays when enabling or disabling the sensor and the time that the light is on when 
the sensor is programmed for lightning control. 

Name 

Channel enable delay 

Values 

From 0 to 65535 

Description  When enabling the channel it does not respond until the enable delay time set has elapsed. 

Name 

Channel disable delay 

Values 

From 0 to 65535 

Description  When disabling the channel, it keeps detecting motion until the disable delay time set has elapsed. 

Name 

Channel switch-off delay 

Values 

From 0 to 65535 

Description 

This  parameter  is  the  time  between  the  last  motion  detection  and  the  sending  of  switch-off  events.  In 

lightning control,  the  switch-off  delay  determines how  long after  a motion  is  detected  the  light  is  to be 

switched off again. With every motion, the sensor is retriggered and the countdown is re-started, so the light 
is not switched off until there is no motion within the delay time 

 

 

 

Содержание KNX SR510000

Страница 1: ...Sensors SR510000 Programming manual...

Страница 2: ...11 3 5 ADVANCED CONFIGURATION 12 3 5 1 Brightness threshold 12 3 5 2 Smoothing and sampling time 12 4 APPLICATION NOTES 13 4 1 MOTION AND BRIGHTNESS DEPENDENT SWITCHING 13 4 1 1 Devices 13 4 1 2 Descr...

Страница 3: ...ection and intruder control It also includes an additional channel that can work in dependence of daylight or permanently depending on the parameterization These types of detectors are indicated to be...

Страница 4: ...US connection terminal KNX Sensor High immunity infrared passive sensor Detection range 5 m at 2 5 m height see next figure Detection channels 2 channels Brightness sensor From 0 to 2550 lux Environme...

Страница 5: ...hannel 1 bit 1 001 4 Channel 1 Master trigger 1 bit 1 001 5 Channel 1 Remaining time s 2 bytes 7 005 6 Channel 2 Motion detection Bit 1 bit 1 001 7 Channel 2 Motion detection Byte 1 byte 5 010 8 Chann...

Страница 6: ...0 Forces a remote end of detection Used for Master Slave mode It allows to emulate a detection without any motion By sending 1 the detector is activated remotely performing the start detection event S...

Страница 7: ...f the slave with this object of the master Name Object 11 Channel 2 Remaining time Brightness threshold Function 2 bytes communication object for reading the remaining time and setting brightness thre...

Страница 8: ...epresents the persistence of the detected movement This value can range between 0 and 10 The greater value the more continuous the movement must be for activation to occur This value must be lesser th...

Страница 9: ...sponse it is measured in microcontroller cycles not seconds Recommended values depending on usage Movement detection example activate lighting 16 Intrusion detection 64 Name Advanced Saturation Values...

Страница 10: ...bject 1 7 Byte when a motion is detected Name Channel 1 2 No motion byte telegram Values From 0 to 255 Description Value sent in object 1 7 Byte after switch off delay Name Channel 1 2 Telegrams when...

Страница 11: ...me Channel disable delay Values From 0 to 65535 Description When disabling the channel it keeps detecting motion until the disable delay time set has elapsed Name Channel switch off delay Values From...

Страница 12: ...t number 11 to set the current brightness level as the new brightness threshold 3 5 2 Smoothing and sampling time The SR510000 is constantly emitting infrared signals The movement detection is based o...

Страница 13: ...and 4 digital outputs 4 1 2 Description Light 1 and 2 are connected to outputs 1 and 2 Z1 and Z2 of the actuator The SR510000 controls the light number 1 by motion detection 15 seconds on The light n...

Страница 14: ...s End of detection event notification yes Ch1 Delays Channel enable delay 0 Channel disable delay 0 Switch off delay 15 Ch2 Event values Bit event off 0 Detection event notification yes End of detecti...

Страница 15: ...t is connected to output 1 Z1 of the actuator and lights are placed along a corridor Three SR510000 sensors one in the middle and another two placed on each side of the corridor will control the light...

Страница 16: ...e Smoothing 2 General Parameters Sampling time 16 Master Ch1 Bit event on 1 Event values Bit event off 0 Detection event notification yes End of detection event notification yes Master Ch1 Channel ena...

Страница 17: ...elay 0 Switch off delay 5 A Smoothing 2 and Sampling time 16 are generally recommended for normal lightning control by motion detection The switch off delay of the master is the time that the light is...

Страница 18: ...me no light is required but when the light is switched on it must be guaranteed to switch off when the room is left The light of the room is connected to the output 1 Z1 of the 6E4S KNX actuator and i...

Страница 19: ...e 16 Ch1 Event values Bit event off 0 Detection event notification No End of detection event notification yes Ch1 Delays Channel enable delay 0 Channel disable delay 0 Switch off delay 30 A Smoothing...

Страница 20: ...s cannot be completely excluded Consequently any liability for this is not accepted Please inform us of any suggestion Every correction will be incorporated in new versions of this manual Manual versi...

Отзывы: