20
82.321-M - Pulvasol 1 and 2 / Pulvigne
- 50 cm to 80 cm above the surface to be treated depending on the spray angle of the nozzles and their
spacing.
If the boom is higher, there is a risk of drift.
HYDRAULIC STIRRING:
- The pump has a fixed output. This output supplies the spray boom. The surplus goes back to the tank via the
flow regulating valve. It is this surplus which provides hydraulic agitation.
HEIGHT OF THE BOOM
STIRRING
DRAINING THE TANK
a
a
b
b
a
b
a
a
b
b
a
b
a
b
According to the cases:
- Place the valve (V1) in position
.
- Place the valve (V2) in position
.
- Place the valve (V4) in position
.
8
V1
V2
V3
V2
V3
V1
V4