16
4)
Loose
strain
relief
by
unscrewing
the
two
strain
relief's
screws
as
in
diagram.
5)
Remove
damaged
supply
cord
set
by
taking
off
the
4
electrical
connection
screws
(block
L1,
N,
L2
and
Ground
screw,
see
diagram)
6)
Insert
the
new
supply
cord
set
in
the
strain
relief
and
lock
it
with
two
strain
relief's
screws
in
suitable
position.
7)
Fix
well
the
ring
terminals
G,
L1,
N,
L2
of
the
new
supply
cord
set
as
shown
in
diagram
with
its
4
screws
8)
Re
‐
install
the
back
enclosure
panel
with
6
screws
9)
Slide
the
appliance
back
into
its
proper
location
10)
Re
‐
connect
the
appliance
to
the
electrical
power.
ELECTRICAL
GROUNDING
This
appliance
is
equipped
with
a
four
‐
prong
plug
for
your
protection
against
shock
hazard
and
should
be
plugged
directly
into
a
properly
grounded
receptacle.
Do
not
cut
or
remove
the
grounding
prong
from
this
plug.