Bernina deco 330 Скачать руководство пользователя страница 1

SERVICE MANUAL

&

PARTS LIST

Deco 330

Содержание deco 330

Страница 1: ...SERVICE MANUAL PARTS LIST Deco 330...

Страница 2: ...ower Shaft Gear 12 Adjusting Upper Shaft Shield Plate Position 13 Adjusting Nedle Thread Tension 14 Adjusting Tension Release Mechanism 15 Changing Thread Tension Unit 16 Replacing Threader Plate and...

Страница 3: ...al Parts 1 Face Cover To remove 1 Remove the Cap and Screw and remove the Face Cover Cap Screw Face cover To attach 2 Attach the Face Cover and tighten Screw then attach the Cap Replacing the face cov...

Страница 4: ...emove the Cap and Screw A 2 Loosen Screw B 3 Lay the machine down on its back and remove Screws C and D then remove the Belt cover Cap Screw A Screw B Screw C Screw D Belt cover To attach 4 Attach the...

Страница 5: ...0 Changing External Parts 3 Base Cover Replacing the base cover To remove 1 Remove Screws 4 pieces to remove the base cover Screw Base cover To attach 2 Follow the above procedure in reverse 1 2 1 1 2...

Страница 6: ...ove the Base lid 1 3 Remove Screws B 2 pcs and remove the Bed cover Screw A Base lid 1 Screw B Bed cover To attach 4 Follow the above procedure in reverse Replacing the base lid 2 To remove 1 Remove S...

Страница 7: ...tension table Accessory To attach 4 Connect the X Y Motor Connectors to the printed circuit board A 5 Insert the X Y Motor cords between the printed cuircuit board A and Arm Make sure that the cords s...

Страница 8: ...Screws C D 5 Disconnect each connector and remove the front cover Note Unlock the Hooks before removing the Front cover Screw A Arm thread guide Lower Screw B Screw C Screw D Hooks 4 spots To attach...

Страница 9: ...belt cover 2 Loosen Screws A and B 3 Raise the handle and remove Screw C and Cap then remove Screw D Remove the Rear cover Screw A Screw B Screw C Cap Screw D Rear cover To attach 3 Follow the above p...

Страница 10: ...cover and loosen Screw move the Needle bar supporter to the right or left until the needle comes to the center of the Needle plate hole 3 Tighten the Screw 4 Attach the face cover 1 Screw 2 Needle ba...

Страница 11: ...ets with the right side of the Needle Tighten Screws 2 pieces of the lower shaft gear 6 Attach the Bobbin holder Needle plate and presser foot 7 Attach the base lid 2 base lid 1 base cover bed cover a...

Страница 12: ...hat the groove on the needle bar is facing right in the front 7 Attach the Bobbin holder Needle plate and presser foot 8 Attach the face cover Needle plate Bobbin holder Screw Needle bar Groove Needle...

Страница 13: ...Adjust the clearance between the Test pin and the Tip of rotary hook 7 to 0 10 to 0 05 mm 6 by moving the Rotary hook set plate 3 up or down 4 Tighten the Screws A 1 B 4 C 2 firmly 5 Check the rotary...

Страница 14: ...with fingers to check the rotary play If the play is larger than 0 8 mm or the gears do not turn smoothly adjust the backlash as follows Adjustment procedure 1 Remove the bed cover See page 4 and loos...

Страница 15: ...ower than 14 2 mm 3 loosen Screw 1 and turn the Upper shaft shield plate in the direction of B 4 Place the right side of the Upper shaft shield plate 2 in the center of the slit of the Upper shaft sen...

Страница 16: ...ely 110 mm sec in the direction of arrow 1 Set the Thread tension dial at 3 2 Lower the presser foot 3 Remove the front cover unit and adjust the thread tension A If the thread tension is more than 59...

Страница 17: ...4 approximately 0 3 0 5 mm and tighten the Screw A 1 4 Raise the presser foot lifter turn the thread tension dial from 9 to 0 make sure the tension disc 5 should open 1 0 mm 6 5 Reattach the front co...

Страница 18: ...cover unit See page 6 2 Remove Screws A 1 B 2 and remove the thread tension unit To attach 3 Follow the above procedure in reverse Note After the replacement adjust Thread Tension Release Machanism a...

Страница 19: ...er plate holder 1 up until it snaps in place Threader plate holder Pin Hook Threader knob Adjustment procedure 1 If the threader hook thrusts or hits against either left or right edge of the needle ey...

Страница 20: ...needle bar and lower the presser foot lifter 3 Insert the 1 2 mm Thickness gauge 1 between the Embroidery Foot P 2 and the needle plate 4 While pressing the Pressure bar actuator 3 down against the up...

Страница 21: ...13 14 10 6 7 8 9 Touch panel LCD Harness Printed circuit board F Black Bobbin winder sensor Blue Upper shaft sensor Black Thread detection sensor Red Presser foot lifter sensor Red 12 8 9 10 11 13 14...

Страница 22: ...2 Pull out the connectors of printed circuit board F LCD Harness Inverter and Touch panel 3 Remove Screws 5 pieces 1 and the Printed circuit board A 2 with the Card guide 3 To attach 4 Follow the abov...

Страница 23: ...Touch panel 8 and press it against the Ribs A B C Fix the Touch panel 8 with the Fixing plate bottom 3 while press it against the Touch panel 8 and tighten screws 2 5 Place the Fixing plate top 1 and...

Страница 24: ...Remove the front cover See page 6 2 Pull out the connectors from the printed circuit board A 3 Remove Screws 1 2 pieces and remove the Printed circuit board F 2 To attach 4 Follow the above procedure...

Страница 25: ...icates the Self Check function keys as shown c Press the Solenoid key on the touch panel and it will indicate Solenoid Key d Press the Solenoid Key several times to check if the Tension disc and Tensi...

Страница 26: ...s and replace the motor To attach 5 Follow the above procedure in reverse Adjusting motor belt tension 1 Tighten Screws 3 2 pieces temporarily 2 Adjust the Belt deflection to about 5 0 mm 5 while pres...

Страница 27: ...ch ON to return the carriage to the home position 4 Remove Screws 4 3 pieces and remove the carriage plate To attach 5 Attach the carriage plate unit and tighten screws temporarily 6 Adjust the carria...

Страница 28: ...power switch ON again to check if the Distance Y 2 is adjusted to 2 5 mm Tighten Screw A 1 4 Loosen screw B 4 and move the X shield plate to adjust the carriage position X 1 5 and X 2 6 Turn the powe...

Страница 29: ...ction loosen the screw A 1 and move the Y sensor fixing plate 8 to adjust If the needle drop position is slightly out of position in the X direction loosen Screw B 5 through the hole of the Sheet cove...

Страница 30: ...To unable the needle thread sensor insert a piece of paper into the channel as shown 8 Run the machine and loosen Screws B 4 2 pieces While the carriage is moving in the direction of arrows 6 adjust t...

Страница 31: ...and fixing plate 3 Pull out the Machine socket unit connector 4 Remove Screw C and remove the Idler 5 Remove Screws D 2 pieces and take out Switching power supply To attach 6 Follow the above procedu...

Отзывы: