EXPRESS DUAL 3000MC
© Bernhard and Company Limited
21
USE A QUALIFIED ELECTRICIAN
In the event of any motor not starting, the following procedure should be adopted:
7.1.
Check that
STOP BUTTON
in control panel on top of machine is not permanently in the
STOP
position (Twist to release if locked down).
7.2
Check fuses - By power inlet / on door of main electrical cabinet.
7.3.
Check that reset button on junction box is not making contact with red button on the
overload. If it is, adjust
RESET
so that it
CLEARS THE BUTTON
, this must be tested with
lid held in position on box (see service Bulletin no.001).
7.4.
Check voltage in electrical box, right hand side of machine - terminal block, terminals 1 & 4.
7.5.
Check for open circuit on overload, terminals 95 and 96, to determine whether or not main
motor is faulty. If open press red resetting button on overload.
7.6.
To determine that all three contactors are OK test each one by pushing the start button
on the individual motors, the contactors should audibly pull in. This can be checked by
someone looking in the junction box while the start buttons are pressed.
7.7.
Traverse
If the contactor is functioning properly check the microswitch. If this is found to be OK
check capacitor if possible. If neither of these is faulty, then the motor is probably at fault.
7.8.
Reel Drive
If the contactor is functioning properly, check the capacitor if possible.
If neither are faulty then the motor is probably at fault.
7.9.
Main Motor
If the contactor is functioning correctly, check the load current with an ammeter across
terminals 2 & 3 on 12 way terminal block. If this exceeds full load current indicated on the
motor identification plate then a new motor is needed. If the reading is below full load
current then possibly the overload is set too low.
NOTE
Before assuming that there is an electrical fault in any of the systems ensure that the
mechanical drive assemblies attached to a particular motor are moving freely, and have
not got increased resistance due to damage, or the build up of dirt. This can best be done
by detaching the motor drive and ensuring that the mechanism is moving freely.
7. Electrical Fault Finding
Содержание EXPRESS DUAL 3000MC
Страница 2: ...Bernhard and Company Limited 2 EXPRESS DUAL 3000MC NOTES...
Страница 26: ...Bernhard and Company Limited 26 EXPRESS DUAL 3000MC NOTES...
Страница 37: ...EXPRESS DUAL 3000MC Bernhard and Company Limited 37 1 2 3 4 5 6 7 8 9 10 11 12 CLAMP ASSEMBLY...
Страница 53: ...EXPRESS DUAL LIFT TABLE Bernhard and Company Limited 53 NOTES...
Страница 57: ...USER MANUAL ADDENDUM NOTES...