Electrical Connection / Code Requirements
The Habanero Heaters require 24VAC power supply (transformer to be supplied by installer). In all
cases, heaters must be electrically grounded in accordance with local codes or in their absence, the
National Electric Code,
ANSI/NFPA 70 in the US, and the
Canadian Electric Code,
CSA C22.1.
Heaters may also be controlled with a manual line switch or timer switch in place of the thermostat.
Refer to wiring diagrams below for guidance on electrical wiring of heaters.
If any of the original wire as supplied with the heater must be replaced, it must be replaced with wiring
having a rating of at least 105°C temperature service and 600 volts capability.
Internal wiring diagram.
Note:
If any of the original wire as supplied with the appliance must be replaced, it must
be replaced with wiring material having a temperature rating of at least 105°C.
IGNITER
BURNER
SENSOR
Pink
Yellow
Red
Brown
Brown
Yellow / Green
Red
Green
Pink
Black
Blue
Green
Brown
Channel Module 50
X-24
Low-Fire
Light
Hi-Fire
Light
Red 24 VAC (Lo)
Blue 24 VAC (Hi)
Green
Green
Gas Valve
C C
M HI
March, 2013