background image

Berner International ("The Company") warrants all new equipment to be free of defects in workmanship and material for a period of 

five years (5 years) on unheated models and two years (2 years) on heated models from the original date of shipment, provided the 

equipment has been properly cared for, installed and operated in accordance with the limits specified on the nameplate and The 

Company’s instructions. 

The Company will correct by repair or replacement, at its option and expense, any proven defects in said apparatus, subject to 

the above conditions, provided that immediate written notice of such defects is given to The Company. The warranty does not 

include any labor incurred for the removal or installation of defective part(s). The Company reserves the right to inspect, or have 

inspected by a qualified representative, any apparatus at the place of installation before authorizing repair or replacement. Repair or 

replacement will be made F.O.B. factory with any applicable transportation charges to be borne by the customer. Merchandise not of  

The Company’s manufacture supplied in piece, or in component assemblies, is not covered by the above warranty, but The Company 

will give the customer the benefit of any adjustment as made with the Manufacturer.

This warranty is void if the apparatus has been tampered with in any way or shows evidence of misuse.

The Company will not assume any expense or liability for repairs made outside its factory without proper written consent from 

its service manager, nor for any transportation charges on apparatus returned to the factory without written authorization by The 

Company. 

Nothing in the above warranty provisions, however, shall impose any liability or obligation of any type, nature or description upon 

Berner International if Berner has not received payment in full for the apparatus in question.

THERE  ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HERE OF INCLUDING

THE IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

LIMITATION OF DAMAGES

Notwithstanding anything to the contrary above, customer’s exclusive remedy for any and all losses or damages resulting 

from the sale of The Company’s equipment under this agreement, including but not limited to, any allegations of breach 

of warranty, breach of contract, negligence or strict liability, shall be limited, at The Company’s option, to either the return 

of the purchase price or the replacement of the particular equipment for which a claim is made and proved. In no event 

shall The Company be liable for any special, consequential, incidental or indirect losses or damages from the sale of The 

Company’s equipment under this agreement.

SERIAL NUMBER

MODEL NUMBER

DATE PURCHASED

 BERNER INTERNATIONAL

 

New Castle, Pennsylvania

 724-658-3551   •   1-800-245-4455   •   www.Berner.com  

©  Copyright 2017  Berner International                                                                                                                                                                                                                                                                                                                MADE IN U.S.A.

Berner reserves the right to alter specifications without prior notice.

Saving energy and creating healthy, comfortable environments

XII. WARRANTY

Содержание AED08

Страница 1: ...ELECTRICAL CONNECTIONS 6 VI FIELD CONNECTIONS 7 VII OPERATING INSTRUCTIONS 7 INTELLISWITCH QUICK START OPERATION 10 FAQ s FREQUENTLY ASKED QUESTIONS 12 VIII MAINTENANCE AND CLEANING 8 IX SERVICE 9 X T...

Страница 2: ...drilling into wall or ceiling do not damage electrical wiring and other hidden utilities F To reduce the risk of fire do not store or use gasoline or other flammable vapors and liquids in the vicinit...

Страница 3: ...ance from combustible material A I R A I R Electrically Heated Units Only INTERIOR EXTERIOR Architectural Elite 8 Simple to Install Easy to operate maintain NOTE Mount large hole of keyhole slots on t...

Страница 4: ...from 0 to 20 toward the door opening If the air stream strikes any obstruction the top edge of the doorway a door opening device etc the effectiveness of the air curtain will be greatly reduced See Fi...

Страница 5: ...two 2 locking screws at the bottom corners 4 Do not install the perforated intake grill or the louvered discharge grill at this time 5 Proceed to Section V ELECTRICAL CONNECTIONS III WALL MOUNTING IV...

Страница 6: ...by lowering the bottom hinged access cover Remove the two bolts located on the intake side of the unit and the access cover will swing down to rest in the vertical position exposing the wiring compar...

Страница 7: ...trolled by the unit mounted sensor a remote mounted thermostator manually through the Intelliswitch located on bottom access cover of the air curtain Overheating protection is provided by auto reset t...

Страница 8: ...e energizing the unit loosening the nozzle vane locking screws and adjusting vanes VIII MAINTENANCE CLEANING Figure 10 20 AIR Discharge Nozzle A I R INTERIOR EXTERIOR 3 12 Handkerchief A I R 8 CAUTION...

Страница 9: ...uild up from the inside of the access cover air inlet grille blower wheels housings interior of the unit and heating coils if applicable Remove the dirt build up from the blower wheels through the dis...

Страница 10: ...ay air curtain becomes active Stop Time Programmable time of day air curtain stops running T Stat Mode Set only heat or heat fan Set Time Day Programmable clock Locked Unit will run as programmed but...

Страница 11: ...curtain turns off Door opens The air curtain activates Door shuts The air curtain continues to run Door opens The air curtain is off Door shuts The air curtain is off OFF 5 Standard Mode of Operation...

Страница 12: ...ice panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device...

Страница 13: ...ain is heated make sure that the thermostat isn t wired to the door switch leads Door switch leads are blue and labeled 9 10 Q How can I check the door switch to be sure it s working A The Intelliswit...

Страница 14: ...ruction or reposition air curtain move out 3 8 for every 1 up from the door Negative pressure Relieve negative pressure by providing make up air UNEVEN AIR Shaft rotating inside fan Tighten set screws...

Страница 15: ...operated in a network there are three options available under the Programming Menu that manage how they interact with each other Door Switch door Thermostat temp Stand By Stby Each option can be set t...

Страница 16: ...bility for repairs made outside its factory without proper written consent from its service manager nor for any transportation charges on apparatus returned to the factory without written authorizatio...

Отзывы: