background image

Thank you for choosing Berner.

 

 

Berner International has been saving energy and creating healthy, comfortable environments for our customers for over 60 years. 

Berner offers unmatched quality, performance, and dependability—not to mention our service.  At Berner, we stand behind our products.

TABLE OF CONTENTS

I. UNCRATING............................................................................................................................................................ ........................................................ 2

II. GENERAL MOUNTING INSTRUCTIONS ................................................................................................................................. ................................... 4

III. WALL MOUNTING  ...................................................................................................................................................................................................... 5 

IV. SUSPENDED MOUNTING ....................................................................................................................................... ................................................... 5

V. ELECTRICAL CONNECTIONS  ..................................................................................................................................................................................... 6

VI. FIELD CONNECTIONS  ................................................................................................................................................................................................ 7

VII. OPERATING INSTRUCTIONS .................................................................................................................................................................................... 7

 INTELLISWITCH™

 

 

QUICK START OPERATION ........................................................................................................................................................................... 10

 

 

FAQ’s (FREQUENTLY ASKED QUESTIONS) ................................................................................................................................................. 12

VIII. MAINTENANCE AND CLEANING ............................................................................................................................................................................ 8 

IX. SERVICE ............................................................................................................................................................... ........................................................ 9 

X. TROUBLESHOOTING ................................................................................................................................................................................................. 14

XI. APPENDIX 

 

A. SERIAL NETWORK CONNECTION (PREVIOUSLY MASTER / SLAVE CONNECTION) ..................................................................................15 

 

B. REMOTE MOUNTED DISPLAY FACEPLATE ................................................................................................................................................ ..... 15 

 

C. INFRA-RED REMOTE ................................................................................................................................................ .......................................... 15 

XII.WARRANTY ................................................................................................................................................ ............................................................... 16

Installation & Maintenance Instructions

Architectural 

Elite 8

www.Berner.com

Air Curtain Series #AED08

II-500D

June, 2017

©Copyright, 2017 Berner International

READ ALL INSTRUCTIONS BEFORE INSTALLING OR USING AIR CURTAIN

indoor use

Содержание AED08

Страница 1: ...ELECTRICAL CONNECTIONS 6 VI FIELD CONNECTIONS 7 VII OPERATING INSTRUCTIONS 7 INTELLISWITCH QUICK START OPERATION 10 FAQ s FREQUENTLY ASKED QUESTIONS 12 VIII MAINTENANCE AND CLEANING 8 IX SERVICE 9 X T...

Страница 2: ...drilling into wall or ceiling do not damage electrical wiring and other hidden utilities F To reduce the risk of fire do not store or use gasoline or other flammable vapors and liquids in the vicinit...

Страница 3: ...ance from combustible material A I R A I R Electrically Heated Units Only INTERIOR EXTERIOR Architectural Elite 8 Simple to Install Easy to operate maintain NOTE Mount large hole of keyhole slots on t...

Страница 4: ...from 0 to 20 toward the door opening If the air stream strikes any obstruction the top edge of the doorway a door opening device etc the effectiveness of the air curtain will be greatly reduced See Fi...

Страница 5: ...two 2 locking screws at the bottom corners 4 Do not install the perforated intake grill or the louvered discharge grill at this time 5 Proceed to Section V ELECTRICAL CONNECTIONS III WALL MOUNTING IV...

Страница 6: ...by lowering the bottom hinged access cover Remove the two bolts located on the intake side of the unit and the access cover will swing down to rest in the vertical position exposing the wiring compar...

Страница 7: ...trolled by the unit mounted sensor a remote mounted thermostator manually through the Intelliswitch located on bottom access cover of the air curtain Overheating protection is provided by auto reset t...

Страница 8: ...e energizing the unit loosening the nozzle vane locking screws and adjusting vanes VIII MAINTENANCE CLEANING Figure 10 20 AIR Discharge Nozzle A I R INTERIOR EXTERIOR 3 12 Handkerchief A I R 8 CAUTION...

Страница 9: ...uild up from the inside of the access cover air inlet grille blower wheels housings interior of the unit and heating coils if applicable Remove the dirt build up from the blower wheels through the dis...

Страница 10: ...ay air curtain becomes active Stop Time Programmable time of day air curtain stops running T Stat Mode Set only heat or heat fan Set Time Day Programmable clock Locked Unit will run as programmed but...

Страница 11: ...curtain turns off Door opens The air curtain activates Door shuts The air curtain continues to run Door opens The air curtain is off Door shuts The air curtain is off OFF 5 Standard Mode of Operation...

Страница 12: ...ice panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device...

Страница 13: ...ain is heated make sure that the thermostat isn t wired to the door switch leads Door switch leads are blue and labeled 9 10 Q How can I check the door switch to be sure it s working A The Intelliswit...

Страница 14: ...ruction or reposition air curtain move out 3 8 for every 1 up from the door Negative pressure Relieve negative pressure by providing make up air UNEVEN AIR Shaft rotating inside fan Tighten set screws...

Страница 15: ...operated in a network there are three options available under the Programming Menu that manage how they interact with each other Door Switch door Thermostat temp Stand By Stby Each option can be set t...

Страница 16: ...bility for repairs made outside its factory without proper written consent from its service manager nor for any transportation charges on apparatus returned to the factory without written authorizatio...

Отзывы: