Electrical safety
The electric motor has been designed for one voltage only.
Always check that the power supply corresponds to the
voltage on the rating plate.
Your tool is double insulated in accordance with
EN 61029; therefore no earth wire is required.
In case of cord replacement the tool must only be
repaired by an authorized service agent or by qualifi ed
electrician.
The following cords are mandatory:
BMS-777
H07RN-F, 2x1.0 mm
2
Mains plug replacement
(U.K. & Ireland only)
DANGER:
•
Should your mains plug need replacing
and you are competent to do this, proceed
as instructed below. If you are in doubt,
contact an authorized Berner repair agent
or a qualifi ed electrician.
•
Disconnect the plug from the supply.
•
Cut off the plug and dispose of it safely;
a plug with bared copper conductors is
dangerous if engaged in a live socket
outlet.
•
Only fi t 13 Amperes BS1363A approved
plugs fi tted with the correctly rated fuse
(1).
•
The cable wire colours, or a letter, will be
marked at the connection points of most
good quality plugs. Attach the wires to their
respective points in the plug (see below).
Brown is for Live (L) (2) and Blue is for
Neutral (N) (4).
•
Before replacing the top cover of the mains
plug ensure that the cable restraint (3) is
holding the outer sheath of the cable fi rmly
and that the two leads are correctly fi xed
at the terminal screws.
WARNING: NEVER
use a light socket.
NEVER
connect the live (L) or neutral (N) wires
to the earth pin marked E or .
Fitting a mains plug to 115 V units
(U.K. and Ireland only)
•
The plug should be fi tted by a competent person. If
you are in doubt, contact an authorized Berner repair
agent or a qualifi ed electrician.
•
The wires are coloured according to the following
code:
live = brown
neutral = blue
•
Do not connect the blue or brown wire to the earth
terminal in the plug. Connect as follows:
brown to terminal marked ‘L’
blue to terminal marked ‘N’
•
The plug fi tted should be comply with BS EN 60309
(BS4343), 16 Amps, earthing contact position 4h.
WARNING:
Always ensure that the cable clamp
is correctly and securely fi tted to the sheath of
the cable.
Using an extension cable
If an extension cable is required, use an approved exten-
sion cable suitable for the power input of this tool (see
technical data).
The minimum conductor size is 1.5 mm
2
. When using
a cable reel, always unwind the cable completely. Also
refer to the table below.
Conductor size (mm
2
)
Cable rating (Amperes)
0.75
6
1.00
10
1.50
15
2.50
20
4.00
25