background image

31

30

D

GB

NL

Berker GmbH & Co

Abt. Service Center
Klagebach 38
D-58579 Schalksmühle
Telefon: 0 23 55 / 90 5-0
Telefax: 0 23 55 / 90 5-111

Funkbus

Gewährleistung

Technische und formale Änderungen am Produkt, so-
weit sie dem technischen Fortschritt dienen, behalten
wir uns vor.

Wir leisten Gewähr im Rahmen der gesetzlichen
Bestimmungen.

Im Gewährleistungsfall bitte an die Verkaufsstelle wen-
den oder das Gerät portofrei mit Fehlerbeschreibung
an unser Service-Center senden.

Guarantee

We reserve the right to make technical and formal
changes to the product in the interest of technical
progress.

Our products are under guarantee within the scope of
the statutory provisions.

If you have a warranty claim, please contact the point
of sale or ship the device postage free with a
description of the fault to the appropriate regional
representative.

Garantie

Wij behouden ons het recht voor om technische en
formele wijzigingen aan het product aan te brengen,
voor zover deze de technische vooruitgang dienen.

Wij bieden garantie in het kader van de wettelijke
bepalingen.

Neem bij garantiekwesties contact op met het verkoop-
punt of stuur het apparaat franco met beschrijving van
de opgetreden defecten naar de desbetreffende
regionale vertegenwoordiging.

Содержание 9450 0200

Страница 1: ...h REG 4 channel Radio controlled switching actuator REG DIN rail type Draadloze schakelactor 4 voudig REG DRA Bestell Nr 9450 0200 Bedienungsanleitung Operating Instructions Bedieningshandleiding 825...

Страница 2: ...led switching of electrical consumers AC 230 V 10 A On reception of a programmed telegram from a radio control detector while off the switching actuator switches on for approx 1 min when it is dark Th...

Страница 3: ...Komfort The desired light scene key must be programmed beforehand into the switching actuator All ON All OFF The programming of a radio channel e g hand held transmitter Komfort always includes the s...

Страница 4: ...trol functions For more information refer to the operating instructions of the radio presence detector Operation With a brief press on the programming buttons Fig A c the outputs A1 to A4 can be switc...

Страница 5: ...t en sluit deze aan overeenkomstig afbeelding B Er kunnen verschillende buitenleiders op de uitgangen A1 t m A4 worden aangesloten Verbind het apparaat via de aansluitklem f met de draadloze ontvanger...

Страница 6: ...nes must not be reversed The distance to electric loads e g microwave ovens hi fi equipment and TV sets and to devices producing stray magnetic fields e g ballasts and transformers must be at least 0...

Страница 7: ...program the transmitter beforehand into the desired channel of the switching actuator Procedure 1 Switch off the lamps connected to the switching actuator by a brief press on the programming button Fi...

Страница 8: ...2 Channel programming Press the desired programming button Fig D c for approx 4 s to activate the programming mode of the desired channel The LED flashes for about 1 min Fig E The radio channel can be...

Страница 9: ...nnel Depress the channel key for more than 1 s Programming a light scene key Depress the light scene key for more than 3 s Programming a detector Remove the battery for about 2 min from the detector A...

Страница 10: ...Important It is not possible to program a combination consisting of presence detector and detector 4 The switching actuator confirms the storage by switching on the respective channel LED permanently...

Страница 11: ...rt always includes the simultaneous and automatic storage of the functions of the All ON or All OFF key Deleting a radio control transmitter A radio control transmitter in the actuator s memory is del...

Страница 12: ...rheits Anwendungen z B Not Aus Not Ruf Die Reichweite eines Funk Systems ist abh ngig von der Leistung der Sender der Empfangscharakteristik der Empf nger der Luftfeuchtigkeit der Montageh he und den...

Страница 13: ...unication across estate boundaries For operation within Germany observe the instructions of the General Approval published in Amtsblatt Vfg 73 2000 If utilized in conformity with its designated use th...

Страница 14: ...ee Screw terminals 1 5 to 4 mm single wire 0 75 bis 4 mm stranded wire without ferrule 0 5 bis 2 5 mm stranded wire with ferrule Receive frequency 433 42 MHz Operating temperature approx 0 C 45 C Stor...

Страница 15: ...ed 1200 VA parallel compensation 920 VA lead lag circuit 2300 VA Energy saving lamps The high peak inrush currents of energy saving lamps during switch on may lead to sticking of the relay contacts Th...

Страница 16: ...ormal changes to the product in the interest of technical progress Our products are under guarantee within the scope of the statutory provisions If you have a warranty claim please contact the point o...

Страница 17: ...32 Mehr Informationen unter Berker GmbH Co KG Postfach 1160 58567 Schalksm hle Germany Telefon 49 0 23 55 905 0 Telefax 49 0 23 55 905 111 www berker de...

Отзывы: