background image

 

 

 
 

Thermostat NO contact with centre plate, time-controlled 

 

G9  
ENERGY-
CONSUMTION TO 
DATE 

Display of the approximate calculated energy consumption/operating 
hours for 

2 DAYS – WEEK – 30 DAYS – YEAR

The current day until the display time is taken into account. 
Calculation: Duty cycle of the heating x COSTS/h 
Select time period for calculating the energy consumption: 

+/– 

Return to the menu: 

OK 

Resetting using 

INSTALLER SETTINGS H9

 

G10  
SET TEMP TO 
READ 

Setting whether the setpoint temperature should be displayed in the 
basic display instead of the current room temperature 
Work setting: 

NO

 – room temperature display 

Select: 

YES/NO

+/–

, press

 OK 

to confirm 

G11  
ADJUST TEMP 

Determining the correction value by which the measured temperature 
should be corrected for display and controller 

  Sensible adjustments: e.g. alignment with calibrated thermometers, 

compensation of installation heights and installation locations that 
are not optimum 

Factory setting: 

0.0

 - no correction 

Adjust correction value: 

+/–

, press 

OK

 to confirm 

G12 
NUMBER FOR 
FLOOR 
TEMPERATURE 

Only when using as floor temperature controller! 
Activating the display of the floor temperature as information number 
The display °C is hidden 
Factory setting: 

NO

 (normal temperature display) 

Select: 

YES/NO

+/–

, press 

OK

 to confirm 

G13 
BACKLIGHT 

Adjusting the display lighting:  

SHORT 

= on for a short time after pressing push-button,  

OFF 

= permanently off 

Factory setting: 

SHORT

 

Set lighting behaviour: 

+/–

, press 

OK

 to confirm 

G14 
LANGUAGE 

Selection of the language for the display text in the display: 

DEUTSCH,

 

ENGLISH

NEDERLANDS,

 

FRANCAIS

 

Select language: 

+/–

, press 

OK

 to confirm 

G15 
INFO 

Display of the controller type and controller version 
Return to menu: 

OK 

G16 
RESET USER 
SETTINGS ONLY 

Resetting the user settings to factory settings 

 The 

counter 

ENERGY-CONSUMTION TO DATE

 is not reset. The 

settings are reset via menu 

H9

Select: 

YES

 (Reset)/

NO

+/–

, press 

OK

 to confirm 

 

Table 2: Overview of the user settings and their selection 

Invoking settings menu 

The display shows 

G1 - PROGRAM SELECT ONE

„

  Select the desired menu using 

+/–

A menu identification and help text are shown at the bottom of the display (12). 

„

  Press 

OK

The first adjustable value flashes in the display. 

„

  Adjust the desired value using 

+/–

„

  Press 

OK

 

 
97-09920-000

 

 

Page 9/15 

10/2011

Содержание 2044 Series

Страница 1: ...mpliant with the guidelines of the EN 60730 and works according to the mode of operation 1C Failure to comply with these instructions may result in damage to the device fire or other hazards These ope...

Страница 2: ...ater is switched on if the room temperature falls below the preset default value Floor thermostat The floor temperature is controlled The heating is switched on if the room temperature measured by the...

Страница 3: ...s using the 9 10 push button if required and press Info OK 11 to confirm Settings The selection of the settings menus is confirmed Carry out further settings with the 9 10 push button and press Info O...

Страница 4: ...the morning and night setback Mon Fri Sat Sun Event C C 1 6 00 21 0 7 00 21 0 2 8 30 18 0 10 00 18 0 3 12 00 21 0 12 00 21 0 4 14 00 18 0 14 00 21 0 5 17 00 21 0 17 00 21 0 6 22 00 15 0 Sat 23 00 Sun...

Страница 5: ...USER SETTING with push button 9 10 and press OK to confirm see operating thermostat G 1 PROGRAM SELECT ONE is displayed Press OK The number of the active program flashes Using select the desired progr...

Страница 6: ...me in the display is saved as the start time of the next interval If flashes in the display then the following event is on the next weekday If OK is pressed the display for the start time changes to t...

Страница 7: ...ters of the set program day profile The presettings of the program correspond to the current day program of Monday Set temperature and events confirm each setting by pressing OK Activation with confir...

Страница 8: ...e electrician Select YES NO heating off on press OK to confirm Display of function 16 OFF Switch on controller again Select any function via the menu or keep Menu s pressed down for 10 s G5 SUMMER WIN...

Страница 9: ...R TEMPERATURE Only when using as floor temperature controller Activating the display of the floor temperature as information number The display C is hidden Factory setting NO normal temperature displa...

Страница 10: ...To enable optimum room temperature control using the internal sensor the installation location selected should allow free air circulation not be located behind curtains cupboards shelves etc not be ex...

Страница 11: ...ipe so that it can be replaced later The wire of the temperature sensor supplies mains voltage and can be extended to 50 m using suitable wires To avoid signal disturbances do not lay the wire of the...

Страница 12: ...Operation H1 APPLICATION Selecting between the thermostat processes according to heating type ROOM Room thermostat FLOOR Floor thermostat LIMITER Room thermostat with limiter Factory settings ROOM Whe...

Страница 13: ...ve is opened daily at 10 00 for the time set here in minutes Factory setting 3 min Set opening time press OK to confirm H6 FROST PROTECTION Setting the frost protection mode and temperature When frost...

Страница 14: ...itch off voltage and switch on again ERR EXT SENSOR Failure short circuit of the external temperature sensor Replace temperature sensor Display range exceeded fallen short of 6 Appendix 6 1 Specificat...

Страница 15: ...vironment It is not possible to enter any data Cause 1 Key lock G6 is active Cancel key lock The desired temperature cannot be set Cause 1 Temperature limit G7 prevents the desired setting Reset tempe...