Thermostat NO contact with centre plate, time-controlled
97-09920-000
Page 8/15
10/2011
When all values have been set, the display returns again to the basic display. The function
is executed.
User settings (Table 2)
The behaviour of the controller is set in the settings menu
User settings
. The settings menu is
accessed via the menu (see Select function). A scrolled text at the bottom of the display makes
the selection easier.
Setting
Description
Operation
G1
SELECT
PROGRAM
Selection of the preset time temperature programs (see Select program)
Factory setting:
1
- Program 1
Select program
1
,
2
or
3
:
+/–
G2
EVENT SETTING
Adjusting a preset time temperature program
Set weekday, temperature, event:
+/–
, press
OK
to confirm (see
Adjusting program)
G3
CLOCK SETTING
Setting the date and time
Set
YEAR
,
MONTH
,
DAY
,
HOUR
,
MINUTE
:
+/–
, press
OK
to
confirm
G4
OFF HEATING
PERMANENT
Switch off the controller, no temperature, frost protection is active, if set
by the electrician.
Select:
YES/NO
- heating off/on :
+/–
, press
OK
to confirm
Display of function (16):
OFF
Switch on controller again: Select any function via the menu or keep
Menu/
s
pressed down for 10 s
G5
SUMMER/WINTER
TIME CHANGE
Select whether or not the summer/winter time change should be carried
out automatically.
Factory setting:
YES
- Switchover on
Select:
YES/NO:
+/–,
press
OK
to confirm
G6
KEY LOCK
Protection of the controller against unauthorized operation
If the key lock is active, no operation is possible
Select:
YES
(key lock)/
NO
:
+/–,
press
OK
to confirm
Cancel key lock again:
Press any push-button, when
CODE
is displayed set
93
using
+/–
and
press
OK
to confirm
G7
TEMP LIMIT
MIN/MAX TEMP
Set parameter of the lower and upper temperature for the controller
Factory setting:
LOWER TEMP LIMIT = 5 °C, UPPER TEMP LIMIT = 30 °C
Set temperatures:
+/–
, press
OK
to confirm
G8
COST/HR
OF ENERGY
Enter the estimated energy costs per hour for the room being controlled.
The calculated consumption is displayed under
G9
.
If the energy costs counter should be used as operating hours
counter, set value
COSTS/h
to
100
.
Factory setting:
10
Set
COSTS/h:
+/–,
press
OK
to confirm