Thermostat NO contact with centre plate, time-controlled 

 
97-09920-000

 

 

Page 8/15 

10/2011

  When all values have been set, the display returns again to the basic display. The function 

is executed. 

User settings (Table 2) 

The behaviour of the controller is set in the settings menu 

User settings

. The settings menu is 

accessed via the menu (see Select function). A scrolled text at the bottom of the display makes 
the selection easier. 

 

Setting 

Description 

Operation 

G1  
SELECT 
PROGRAM 

Selection of the preset time temperature programs (see Select program)

 

Factory setting: 

1

 - Program 1 

Select program 

1

2

 or 

3

+/–

 

G2 
EVENT SETTING 

Adjusting a preset time temperature program 
Set weekday, temperature, event: 

+/–

, press 

OK

 to confirm (see 

Adjusting program) 

G3  
CLOCK SETTING 

Setting the date and time 
Set 

YEAR

,

 MONTH

,

 DAY

,

 HOUR

,

 MINUTE

+/–

, press

 OK 

to

 

confirm 

G4 
OFF HEATING 
PERMANENT 

Switch off the controller, no temperature, frost protection is active, if set 
by the electrician. 
Select: 

YES/NO

 - heating off/on : 

+/–

, press 

OK 

to confirm

 

Display of function (16): 

OFF

 

Switch on controller again: Select any function via the menu or keep 

Menu/

s

 pressed down for 10 s 

G5  
SUMMER/WINTER 
TIME CHANGE 

Select whether or not the summer/winter time change should be carried 
out automatically. 
Factory setting: 

YES

 - Switchover on 

Select: 

YES/NO:

 

+/–,

 press 

OK 

to confirm 

G6  
KEY LOCK 

Protection of the controller against unauthorized operation 
If the key lock is active, no operation is possible 
Select: 

YES

 (key lock)/

NO

+/–,

 press

 OK 

to confirm 

Cancel key lock again:  
Press any push-button, when 

CODE

 is displayed set 

93

 using 

+/–

 and 

press 

OK

 to confirm 

G7  
TEMP LIMIT 
MIN/MAX TEMP 

Set parameter of the lower and upper temperature for the controller 
Factory setting:  

LOWER TEMP LIMIT = 5 °C, UPPER TEMP LIMIT = 30 °C

 

Set temperatures: 

+/–

, press 

OK

 to confirm 

G8  
COST/HR 
OF ENERGY 

Enter the estimated energy costs per hour for the room being controlled. 
The calculated consumption is displayed under 

G9

  If the energy costs counter should be used as operating hours 

counter, set value 

COSTS/h

 to 

100

Factory setting: 

10

 

Set

 COSTS/h:

 

+/–,

 press

 OK 

to confirm

 

 

Содержание 2044 Series

Страница 1: ...mpliant with the guidelines of the EN 60730 and works according to the mode of operation 1C Failure to comply with these instructions may result in damage to the device fire or other hazards These ope...

Страница 2: ...ater is switched on if the room temperature falls below the preset default value Floor thermostat The floor temperature is controlled The heating is switched on if the room temperature measured by the...

Страница 3: ...s using the 9 10 push button if required and press Info OK 11 to confirm Settings The selection of the settings menus is confirmed Carry out further settings with the 9 10 push button and press Info O...

Страница 4: ...the morning and night setback Mon Fri Sat Sun Event C C 1 6 00 21 0 7 00 21 0 2 8 30 18 0 10 00 18 0 3 12 00 21 0 12 00 21 0 4 14 00 18 0 14 00 21 0 5 17 00 21 0 17 00 21 0 6 22 00 15 0 Sat 23 00 Sun...

Страница 5: ...USER SETTING with push button 9 10 and press OK to confirm see operating thermostat G 1 PROGRAM SELECT ONE is displayed Press OK The number of the active program flashes Using select the desired progr...

Страница 6: ...me in the display is saved as the start time of the next interval If flashes in the display then the following event is on the next weekday If OK is pressed the display for the start time changes to t...

Страница 7: ...ters of the set program day profile The presettings of the program correspond to the current day program of Monday Set temperature and events confirm each setting by pressing OK Activation with confir...

Страница 8: ...e electrician Select YES NO heating off on press OK to confirm Display of function 16 OFF Switch on controller again Select any function via the menu or keep Menu s pressed down for 10 s G5 SUMMER WIN...

Страница 9: ...R TEMPERATURE Only when using as floor temperature controller Activating the display of the floor temperature as information number The display C is hidden Factory setting NO normal temperature displa...

Страница 10: ...To enable optimum room temperature control using the internal sensor the installation location selected should allow free air circulation not be located behind curtains cupboards shelves etc not be ex...

Страница 11: ...ipe so that it can be replaced later The wire of the temperature sensor supplies mains voltage and can be extended to 50 m using suitable wires To avoid signal disturbances do not lay the wire of the...

Страница 12: ...Operation H1 APPLICATION Selecting between the thermostat processes according to heating type ROOM Room thermostat FLOOR Floor thermostat LIMITER Room thermostat with limiter Factory settings ROOM Whe...

Страница 13: ...ve is opened daily at 10 00 for the time set here in minutes Factory setting 3 min Set opening time press OK to confirm H6 FROST PROTECTION Setting the frost protection mode and temperature When frost...

Страница 14: ...itch off voltage and switch on again ERR EXT SENSOR Failure short circuit of the external temperature sensor Replace temperature sensor Display range exceeded fallen short of 6 Appendix 6 1 Specificat...

Страница 15: ...vironment It is not possible to enter any data Cause 1 Key lock G6 is active Cancel key lock The desired temperature cannot be set Cause 1 Temperature limit G7 prevents the desired setting Reset tempe...